Low air output
The air intake section is clogged up.
➤
Remove any leaves and other
dirt from the ventilation grilles
of the roof air conditioner.
The blower is defective.
➤
Contact an authorised work-
shop.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
➤
Clean the drainage openings
for condensation water.
The seals are damaged.
➤
Contact an authorised work-
shop.
Roof air conditio-
ner does not
switch on.
No supply voltage (230 V
w
) connec-
ted.
➤
Check the power supply.
The voltage is too low (under
200 V
w
).
The voltage converter is defective.
➤
Contact an authorised work-
shop.
The capacitor is defective.
One of the temperature sensors is
defective.
The electrical fuse of the power sup-
ply is too low.
➤
Check the electrical fuse of the
power supply.
Roof air conditio-
ner does not
switch off.
One of the temperature sensors is
defective.
➤
Contact an authorised work-
shop.
The thermal protection is defective.
The capacitor is defective.
The electrical fuse of the power sup-
ply is too low.
Power supply is too low.
Problem
Cause
Remedy
Summary of Contents for B1600PLUS
Page 2: ......
Page 3: ...B1600PLUS B2200 B2600 3 4 5 2 1 3 1 B1600PLUS B2200 4 5 2 1 3 2 B2600 ...
Page 5: ...B1600PLUS B2200 B2600 5 1 2 3 4 1 5 6 7 ...
Page 6: ...B1600PLUS B2200 B2600 6 1 8 1 1 9 0 ...
Page 7: ...B1600PLUS B2200 B2600 7 1 2 a 980 280 560 280 650 550 235 50 310 670 min 30 max 80 b ...
Page 385: ......
Page 386: ......
Page 387: ......