Troubleshooting
Once per year
Check the profile seals:
➤
Check the seal between the roof air conditioner and the roof of
the vehicle for cracks and other damage.
Once per year
Have the heat exchanger serviced:
➤
Have the heat exchanger of the roof air conditioner serviced
by specialist workshop.
Once per year
Replace the carbon filter:
➤
Manually take off the filter cover (fig.
0
, page 6).
➤
Remove the filter (fig.
a
1, page 3).
➤
Remove the carbon filter (fig.
a
2, page 7).
➤
Put a new carbon filter in.
➤
Clean the filter with a detergent solution and let it dry.
➤
Put the dry filter back in.
➤
Put the cover back on.
Problem
Cause
Remedy
No cooling
capacity
The roof air conditioner is not set to
cooling.
➤
Set the roof air conditioner to
cooling.
The ambient temperature is above
50 °C.
The roof air conditioner is only
designed for ambient tempera-
tures of up to 50 °C.
The temperature set is higher that the
room temperature.
➤
Select a lower temperature.
The ambient temperature is below
16 °C.
The roof air conditioner is only
designed for ambient tempera-
tures above 16 °C.
One of the temperature sensors is
defective.
➤
Contact an authorised work-
shop.
The vaporiser fan is damaged.
The compressor is defective.
The heat exchange battery is pollu-
ted.
The condenser fan is damaged.
Interval
Inspection/maintenance
Summary of Contents for B1600PLUS
Page 2: ......
Page 3: ...B1600PLUS B2200 B2600 3 4 5 2 1 3 1 B1600PLUS B2200 4 5 2 1 3 2 B2600 ...
Page 5: ...B1600PLUS B2200 B2600 5 1 2 3 4 1 5 6 7 ...
Page 6: ...B1600PLUS B2200 B2600 6 1 8 1 1 9 0 ...
Page 7: ...B1600PLUS B2200 B2600 7 1 2 a 980 280 560 280 650 550 235 50 310 670 min 30 max 80 b ...
Page 385: ......
Page 386: ......
Page 387: ......