EN
RM5310, RM5330, RM5380
Installing the refrigerator
21
6.2
Installing the refrigerator in a draught-proof location
Gas-powered refrigerators in caravans or motorhomes must be installed in a
draught-free location according to EN 1949. This means that the combustion air is
not extracted from the interior and the exhaust fumes are prevented from directly
entering the living space.
A suitable seal must be fitted between the rear panel of the refrigerator and the inte-
rior of the vehicle.
!
The manufacturer recommends using a flexible seal to ease removal and installation
for maintenance purposes.
➤
Attach the sealing lips (fig.
1, page 5) to a stop rail behind the refrigerator, for
example, by using an adhesive.
➤
When installing, push the refrigerator against the stop rails with the sealing lips.
This then seals the space behind the refrigerator to the interior of the vehicle.
6.3
Creating the air vents
I
➤
Make an air inlet vent and an air outlet vent in the outer wall with the size of
451 mm x 156 mm. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 19.
If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤
Make an air inlet vent in the floor (fig.
4, page 4) behind the refrigerator near
the gas burner with a diameter of at least 40 mm. The vent pipe must lead directly
outside. This allows leaking unburned gas to escape outside.
➤
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig.
WARNING! Fire hazard!
Do not use flammable materials such as silicone sealants, foam or similar
for the draught-proof installation.
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
DometicRM53xx_INM_4445102229_EMEA(en-de-fr-nl)_20xx-xx-xx.book Seite 21 Dienstag, 30. März 2021 10:54 10