EN
Installing the refrigerator
RM5310, RM5330, RM5380
20
•
The refrigerator must be installed in a recess so that it stands firm when the vehicle
is in motion. Note the following dimensions here (H x W x D in mm, fig.
page 3):
–
RM 5310
: 618 x 486 x 474
–
RM 5330
: 821 x 486 x 474
–
RM 5380
: 821 x 486 x 474
•
The outer wall must be fitted with an air inlet vent (fig.
2, page 4) and an outlet
3, page 4) with ventilation grilles so that the heat generated can be
easily released to the outside:
–
Air inlet vent: Fit the ventilation grille as flush as possible underneath the
burner lid (fig.
1, page 4) with a minimum cross-section of 250 cm
2
.
–
Outlet vent: fit above the refrigerator as far as possible. A ventilation grille
with integrated flue duct can also be used here.
•
If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig.
5, page 4) must be provided in the floor for
releasing leaked gas.
•
For the RM5380 refrigerators, an air inlet vent (fig.
5, page 4) must always be
installed in the floor.
•
The air vents must not be covered by vehicle parts (such as an open door or by
installing accessories such as bicycle racks) while operating.
•
There must be sufficient space at the back of the refrigerator for the air to be able
to circulate around the cooling element.
•
Fit a heat conduction plate (fig.
4, page 4) above the refrigerator so that the
heat does not accumulate in the vehicle.
•
Install the refrigerator so that it is protected from excessive heat, as this leads to
poor performance and increases the power consumption of the refrigerator.
•
The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and EN 1648-2.
•
The gas installation must comply with national and local regulations.
European standard: EN 1949.
•
The refrigerator must be installed in a draught-proof location in accordance with
EN 1949, see chapter “Installing the refrigerator in a draught-proof location” on
page 21.
DometicRM53xx_INM_4445102229_EMEA(en-de-fr-nl)_20xx-xx-xx.book Seite 20 Dienstag, 30. März 2021 10:54 10