EN
Connecting the refrigerator
RM5310, RM5330, RM5380
26
9.2
Connecting to 12 V
g
and 230 V
w
A
I
➤
Connect the RM5310 /RM5330 /RM5380 refrigerators according to fig.
page 12 (without lighting), and fig.
, page 13 (with lighting):
NOTICE!
•
The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable regulations and
standards.
•
According to EN 1648-1, the respective negative and positive cables
of the DC connections for heating and lighting may not be joined
with one another in a caravan. This can cause electrical interference
or damage to electrical components.
•
The inverter may only be connected by a specialist.
NOTE
•
The mains socket must be easily accessible so that you can unplug
the power cord if required, thereby disconnecting the refrigerator
from the power.
•
The plug of the AC connection cable must not be cut off.
•
The connection cables must be laid so that they do not come in con-
tact with hot parts of the unit/burner or with sharp edges.
•
Changes to the internal electrical installation or the connection of
other electrical components (e.g. extra third party fans) to the inter-
nal wiring of the refrigerator will void the E1/CE approval and any
claims from the guarantee and product liability.
Item
Description
1
Heating element DC
2
DC connection cable
3
Terminal strip for the DC power supply of the heating cartridge
4
Positive cable of the heating cartridge
5
Earth cable of the heating cartridge
6
Positive cable of the lighting
7
Reed contact switch (sensor switch)
8
Galvanometer
9
LED lighting
10
Thermal power adapter
DometicRM53xx_INM_4445102229_EMEA(en-de-fr-nl)_20xx-xx-xx.book Seite 26 Dienstag, 30. März 2021 10:54 10