5. Ensure that the joint has not overly deformed
and caused gaps between the bottom roof
flange and ceiling. If this occurs, increase the
total length of the sleeves by 5 mm, or
unscrew by half a turn.
If there is no deformation (sleeves too long), then
there will be insufficient clamping of the joint. In
that case the sleeves must be shortened by 5 mm
by choosing a different combination of 10 mm and
5 mm long sleeves.
6. Ensure that the filter is inserted into the filter
holder, and the filter holder inserted into the
product.
7. Close the ceiling cover.
✔
The installation is complete.
Operation
Ventilation while driving
Observe the following notes:
• In extremely heavy or prolonged rain, a small
amount of water is expected to reach the filter.
• In that case no additional care or steps need to
be taken.
– Keep the filter in the filter holder for the water
to evaporate.
The product operates automatically from vehicle
speeds of 25 km/h.
The product is suitable for use in the rain.
➤
Prior to travel ensure that the blocker plate is
Otherwise the product will not function to
reduce dust entry.
Ventilation while stationary
Observe the following notes:
• Cross-flow ventilation is still maintained with the
blocker plate fitted.
• Do not block any openings around or inside the
product. All air paths (excluding the filter) are
required for free ventilation.
The product provides 150 cm
2
of passive ventila-
tion via a secondary air path through the ventilation
chamber (fig.
1, page 11). Air bypasses the filter
2, page 11) when the vehicle is stationary
only. This is required to maintain fresh air
exchange. A small amount of airflow around the
vent may be noticeable.
If the product is used as the primary ventilation
point of the vehicle without any additional ventila-
tion possibilities:
➤
Check local regulations regarding passive
ventilation and add according warning labels to
the ceiling cover.
The warning labels must be well visible.