background image

7

Example of the DME-LAN-002 Connection

A

B

D

G

N

1      2     3    

IN 100-240V      /50-60 Hz

L

ta -10°c to +45°c

N

w w w . d o m e s t i a . b e
Made in Belgium

DME-LAN-002

26

25

A

D

G

N

RS485 Captor

27      28     29      30     31  

B

D

G

N

+

16

V

+12 V

Captor

39      40                    43      44                    47     48                     51     52

Line 1

Line 2

Line 3

Line 4

24

NC

RJ45

6      7     8

A

G

B D

N

RS485

Slave

IN 230V~ 50 Hz

L

OUT1

OUT2

2,6W ta -10°c to +45°c

OUT3

OUT4

N

D

A B G

RS485

N

250W

250W

250W

250W

RS1

T1 T2 T3 T4

charge 

setting

1 2 3 4

ON  DIP

RS2

27

28

30

31

33

34

36

37

50 51 52

22

23

25

26

IN

1

IN

2

IN

3

IN

4

AL

O

FF

8

9

10 11

AL

O

N

12 13

JP1

Standalone Inputs 

(Remove JP1)

DML-004-002

ON  DIP

DMC-012-002

A
B
C
D
E

*(1)

1

2

3

4

5

6

7

8

9

10

11

12

Gauche

Droite

Haut

Bas

Centre

8

A

8

A

8

A

8

A

8A

8A

8A

8A

8A

8A

8

A

8

A

A

G

D

N

B

DMC-012-002

A
B
C
D
E

*(1)

1

2

3

4

5

6

7

8

9

10

11

12

Gauche

Droite

Haut

Bas

Centre

8

A

8

A

8

A

8

A

8A

8A

8A

8A

8A

8A

8

A

8

A

A

G

D

N

B

UTP,

VVT

L

N

L

N

L

N

Ph

N

IN 230VAC

Summary of Contents for DME-LAN-002

Page 1: ...www domestia be USERS MANUAL DME LAN 002 Master control module...

Page 2: ...2...

Page 3: ...nt of the DME LAN 002 14 4 6 Installation composition 14 4 7 Configuring the slave cards 16 4 8 Configuring the output names 18 4 9 Configuration of the group 19 4 10 Configuring areas 23 4 11 Configu...

Page 4: ...sensor s DMCT 001 001 The Home Manager application is available for free from the Android Apple and Windows stores It loads web pages that the user can open with any Internet browser Safari Chrome Fi...

Page 5: ...boxes it is best to use a UTP cable with a pair for terminal 6 A and 7 B and a pair for terminal 8 GND Terminals 1 2 and 3 RJ45 make it possible to connect the DME LAN 002 card to the Ethernet networ...

Page 6: ...AN 002 26 25 A D G N RS485 Captor 27 28 29 30 31 B D G N 16 V 12 V Captor 39 40 43 44 47 48 51 52 Line 1 Line 2 Line 3 Line 4 24 NC RJ45 6 7 8 A G B D N RS485 Slave To temperature sensor see instructi...

Page 7: ...10 c to 45 c OUT3 OUT4 N D A B G RS485 N 250W 250W 250W 250W RS1 T1 T2 T3 T4 charge setting 1 2 3 4 ON DIP RS2 27 28 30 31 33 34 36 37 50 51 52 22 23 25 26 IN1 IN2 IN3 IN4 ALL OFF 8 9 10 11 ALL ON 12...

Page 8: ...cation modules 3 NETWORK CONNECTION 3 1 CONFIGURATION OF THE IP ADDRESS When you switch the DME LAN on if it is connected to a modem or router it will automatically adapt its IP address to be compatib...

Page 9: ...ION OF A NETWORK No Internet connection is required to configure the DME LAN However you must connect it directly to your PC via a wired network in this case the PC s IP address must be configured man...

Page 10: ...uter label via Wi Fi SSID TP LINK_ Enter the password indicated on the router label Key Launch Home Manager and click on the magnifying glass in the settings to check for the presence of the managemen...

Page 11: ...THE INSTALLER APPLICATION 4 1 LAUNCH Download Home Manager in advance from Apple iOS Android or from the downloads page of our website www domestia be Then click on the Home Manager icon to access the...

Page 12: ...UAGE Click on Language Installer bulb icon Then click on the corresponding flag to choose your language 4 3 ENTER YOUR INSTALLER DETAILS Once your data has been validated you will return to the home s...

Page 13: ...A magnifying glass icon allows you to configure the IP address automatically If you see a No DME LAN connected message refer to point 3 1 Please refer to point 3 1 to change the IP address of the DME...

Page 14: ...on If the connection with the DME LAN 002 is possible tablet computer smartphone and DME LAN 002 is connected via a network and the IP parameters are compatible the application will read the content o...

Page 15: ...hen configuring the card s address For cards with 4 outputs the graphic indicates the numbering to be applied to the encoding wheels Add the type and exact number of cards that are included in your in...

Page 16: ...this in time cut the power to the card and repeat the action DMC 012 002 A B C D E By this stage you have configured the card as a slave to the DME LAN 002 All that remains is to establish the addres...

Page 17: ...can press the central button to validate and your card will switch into RUN mode LED AE For extensions with 4 outputs DMC 004 003 DMA 004 003 DML 004 002 DMD 004 00 Simply turn the encoding wheels to...

Page 18: ...ts 4 8 CONFIGURING THE OUTPUTS To configure an output just click on its name A window will open allowing the name to be configured You can enter a maximum of 20 characters including spaces its type an...

Page 19: ...is still active then the relay is deactivated A long press activates the relay for the maximum possible time 16 hours Continuous mode Each press of the button activates the output for the time configu...

Page 20: ...20...

Page 21: ...uts while the button is pressed 5 Open all group This group is used to activate the open shutters outputs A short press activates the outputs for the opening time that has been configured for these ou...

Page 22: ...to inactive Yellow ON Grey OFF Outputs that are not included in the group are listed in the column on the right For dimmer outputs you can define the dimming level of the bulk between 0 100 Note that...

Page 23: ...that must be part of the group An output can be added by clicking on the list on the right It can be deleted by clicking the bin icon on the left before and after selecting the outputs concerned Click...

Page 24: ...e sensor must be connected to a relay via the configuration menu for relay outputs Automatic mode uses the settings programmed by time slots maximum of six events per day The settings span 0 50 C in i...

Page 25: ...25 4 12 SAVING THE CONFIGURATION IN THE DME LAN Press on the icon to save your configuration A progress bar is displayed and the configuration is saved after a few seconds...

Page 26: ...lighting value between 0 and 255 To use a device that operates using the DMX 512 protocol you need to add a module with an equivalent function in the installation composition see 4 6 Installation comp...

Page 27: ...put The output is activated and you simply need to press the button s to assign it them to this output Press the button again to finish 5 2 PROGRAMMING GROUPS In order to assign one or more buttons to...

Page 28: ...s PC an Android smartphone an iOS tablet etc However some browsers are not fully compatible In order to access the DME LAN 002 web interface you simply need to enter the IP address of the latter in yo...

Page 29: ...active or inactive Yellow active Grey inactive 6 2 TEMPERATURE MENU The Temperature menu is used to manage the temperature sensors The selected sensor appears in a light colour The colour of the butt...

Page 30: ...to save the configuration The second frame is used to configure the temperature settings for events Select the day to be configured in Day then configure the events in chronological order Unused even...

Page 31: ...ch the event occurs the Event time The Save button is used to save the configuration There are three possible event types Standard An event that takes place at a set time Sunrise The event takes place...

Page 32: ...from sunset can be defined The event takes place at sunset An offset of between 127 minutes and 128 minutes from sunset can be defined In this example outputs 1 to 3 are lit and output 4 is off at th...

Page 33: ...0 In order to restore this default IP address if the address is unknown simply press the reset button on the card five times The second frame figure below is used to configure the time date and day of...

Page 34: ...ffers remote management that lets you manage your installation at any time from anywhere in the world via your Smartphone tablet or PC Go to https my domestia com to access Home On Web 1 When you reac...

Page 35: ...35 2 When you reach the Log in page click on Create an account 3 You can then manage your different areas via this intuitive platform...

Page 36: ...tab allows you to automatically adjust your heating remotely and or to view your sensors 5 In the Events tab you can determine the actions that will automatically be executed either at a certain time...

Page 37: ...By default the IP address of the DME LAN ends in 210 The application tablet smartphone or PC is on a different network to the DME LAN 002 Connect the device or DME LAN 002 to the correct network I am...

Page 38: ...AN via the RS485 slaves port next to the RJ45 connector 9 WARRANTIES Warranty conditions The duration of your product s basic warranty is 2 years starting from the date your order is received Please k...

Page 39: ...39...

Page 40: ...40 rue Jean Jaur s 176 4430 Ans Belgium Tel 32 4 372 07 16 Fax 32 4 372 07 19 info domestia be...

Reviews: