Mouser Advanced User Manual

Inclusion & Exclusion

Inclusion

Follow the instructions for your Z-Wave Certified controller to enter inclusion 
mode.  When prompted by the controller:

1.  Bring the Mouser to within 10’ of your Z-Wave controller for the inclusion 

process.  After successful pairing, the device can be brought to the de-
sired location.

2.  Remove top cover by sliding it back and lifting up.
3.  Insert batteries.
4.  Press the CONNECT BUTTON quickly 3 times in a row.

The LED INDICATOR will flash five times indicating inclusion

Exclusion

Follow the instructions for your Z-Wave Certified controller to enter exclusion 
mode.
When prompted by the controller:

1.  Remove top cover by sliding it back and lifting up.
2.  Press the CONNECT BUTTON quickly 3 times in a row.

The LED INDICATOR will flash five times indicating exclusion/disconnection.

Inclusion & Exclusion

Summary of Contents for DMMZ1

Page 1: ...Always Connected Always Covered Mouser User Manual DMMZ1 ...

Page 2: ...sic user please visit www domeha com for instructions This manual will provide in depth technical information about the Mouser especially in regards to its compliance to the Z Wave standard such as compatible Command Classes Association Group ca pabilities special features and other information that will help you maximize the utility of this product in your system Preface ...

Page 3: ...cription Features 4 Specifications 5 Physical Characteristics 6 Inclusion Exclusion 7 Factory Reset Misc Functions 8 Physical Installation 9 LED Behavior 10 Button Behavior 11 Compatible Command Classes 12 Configuration Command Class Parameters 14 Troubleshooting 16 Warranty Support 17 ...

Page 4: ...l send a Z Wave signal to its con troller to notify the user and will not retrigger until the trap is reset Key Features Z Wave Plus Certified Up to 150 wireless range depending on environment Quick and painless for both the mouse and the human Mess free rodent removal Will work with or without Z Wave connectivity Physical arm disarm button for added safety Two Year Battery Life equivalent to 50 z...

Page 5: ...WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE NO OTHER PERSON OR REPRE SENTATIVE IS AUTHORIZED TO MAKE ANY OTHER WARRAN TY ON BEHALF OF ECP OR ASSUME FOR ECP ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PROD UCT IN NO EVENT WILL ECP BE LIABLE FOR ANY DAMAGES INCLUDING BUT NOT LIMITED TO INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY ...

Page 6: ...d in Figures 1 2 will be used throughout this manual Please refer to this page as needed MAIN BODY ARM DISARM BUTTON TOP COVER LED INDICATOR BATTERY COMPARTMENT CONNECT BUTTON Figure 1 Parts of the Mouser BAIT HOLDER Figure 2 Removing the BAIT HOLDER Physical Characteristics ...

Page 7: ... sired location 2 Remove top cover by sliding it back and lifting up 3 Insert batteries 4 Press the CONNECT BUTTON quickly 3 times in a row The LED INDICATOR will flash five times indicating inclusion Exclusion Follow the instructions for your Z Wave Certified controller to enter exclusion mode When prompted by the controller 1 Remove top cover by sliding it back and lifting up 2 Press the CONNECT...

Page 8: ...e lease A flashing LED INDICATOR indicates a successful factory reset 3 The Mouser s memory will be erased to factory settings Waking Up The Mouser Because the Mouser is a battery powered device it wakes up on regular inter vals to give battery and other status updates to the controller as well as to ac cept configuration settings from the controller This helps to extend the battery life The devic...

Page 9: ...n the desired location rodents usually scurry around walls and other corners 3 Flip On Off Button to the On position the LED will stay lit for two seconds indicating the Mouser is armed A flashing LED indicates low battery 4 When the Mouser is tripped the LED will blink every five seconds and an alert will be sent to your Z Wave Controller 5 Flip the On Off Button to the Off position to empty the ...

Page 10: ...ed in a system Stay on for 2 seconds straight the CONNECT BUTTON is pressed and held for 10 seconds resetting Mouser to factory settings OR the CONNECT BUTTON is pushed once Blinks once every 3 seconds the trap is tripped and needs to be emptied Stays on for 2 seconds Battery is high when the ARM DISARM BUTTON is pushed to the Arm Position Blinks three times Battery is low when the ARM DISARM BUTT...

Page 11: ...he system and removes the Home ID from its memory Mouser Not Yet Included in System and Controller is in Inclusion Mode Device enters inclusion mode and includes into whichever network is also in inclusion mode Press and hold CONNECT BUTTON for 10 seconds Mouser Already Included in System Device will be reset to factory settings and a DEVICE_RESET_LOCALLY command will be sent to Node 1 Press and H...

Page 12: ... the main Z Wave controller The Door Window Sensor sends this group a Notification Report and a Binary Sensor Report when it is tripped reset armed and disarmed It also sends this group a Battery Report in reponse to Battery Get commands Group 2 The Mouser sends a Basic Set command to Association Group 2 or the Control Group to directly trigger devices like a light chime etc when it is tripped Aft...

Page 13: ...ation Trap Unarmed 04 Trap Re Arm Required Unknown Location Sequence Reserved Event Parameters Length 00 Notification Event Parameters 00 No Event Parameters Returned Value 00 00 00 FF 07 XX 00 00 V1 Alarm Type t 00 Unsupported V1 Alarm Level 00 Unsupported Reserved 00 Reserved Notification Status FF Unsolicited Reporting is Enabled Notification Type 07 Home Security Event Pest Exterminated 08 Mot...

Page 14: ...first minute and it is pulsed at approximately 400 beats per minute for the remainder of the time 01 Set Firing Mode 01 Continuous Fire 02 Burst Fire 02 Burst Fire 3 02 High Voltage Duration Time 00 64 01 68 100 360 in Seconds 64 100 Seconds Table 6 Mouser Configuration Parameters Configuration parameters are sent using a standard syntax to ensure interopera bility between all manufacturers produc...

Page 15: ...r LED alarm when the trap is tripped 01 Enable Disable LED Alarm 00 LED Alarm Disabled 01 LED Alarm Enabeled 01 LED Alarm Enabeled 5 This parameter sets the amount of time the LED Indicator blinks after the trap is tripped 01 LED Alarm Duration 00 LED Alarm Blinks Until Trap is Cleared 01 FF 1 255 in Hours 00 LED Alarm Blinks Cleared Table 7 Mouser Configuration Parameters ...

Page 16: ...Our Quick Start Guides have all you need to start using any device For more thorough information about Z Wave home automation visit www domeha com support Q Q I ve tried multiple times but I can t include the Mouser in my sys tem A A Make sure your device is getting power Then follow the procedure to Factory Reset on Page 8 and try going through the inclusion process again If you are still having ...

Page 17: ...al use in the United States or Canada To obtain warranty service during the Warranty Period call Dome Customer Service 1 855 249 1754 or email support domeHA com for instructions on sending damaged parts and documentation for a Return Material Authorization RMA Products returned to ECP for repair or replacement without au thorization will be returned at the sender s expense All warran ty claims mu...

Reviews: