![Dome DMMZ1 User Manual Download Page 12](http://html.mh-extra.com/html/dome/dmmz1/dmmz1_user-manual_2517699012.webp)
Page 12
Mouser Advanced User Manual
Compatible Command Classes
Command Class
Notes
Device Reset Locally V1 (5A)
-
Powerlevel V1 (73)
-
Association Group Information V1 (59)
-
Battery V1(80)
-
Z-Wave Plus Info V2 (5E)
Returned Value:
01 06 00 0C 07 0C 07
Z-Wave Plus Version:
01
Role Type
: 06
(Slave Sleeping Reporting)
Node Type
: 00
(Z-Wave Plus Node)
Installer Icon Type
: 0C 07
(Home Security Alarm)
User Icon Type
: 0C 07
(Home Security Alarm)
Version V2 (86)
Returned Value:
06 04 05 03 10 52 00
Z-Wave Library Type:
06
(Enhanced Slave)
Protocol Version
: 04 05
Protocol Sub-Version
: 03 10
Application Version
: 52
Application Sub-Version
: 00
Association V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold five members, typically
including the main Z-Wave controller. The Door/Window Sensor sends
this group a Notification Report and a Binary Sensor Report when it is
tripped, reset, armed, and disarmed. It also sends this group a Battery
Report in reponse to Battery Get commands.
Group 2
The Mouser sends a Basic Set command to Association Group 2 (or the
Control Group) to directly trigger devices (like a light, chime, etc.) when
it is tripped. After the trap is reset, a BASIC_SET(00) command is sent
to reset the device (e.g. turn off the light.) The value of the Basic Set
command (e.g. brightness of the lamp) is configured using configuration
parameter 1.
Group 3
Group 3 supports up to 5 members and the Mouser sends it a NOTIFICA-
TION_REPORT when tripped, reset, armed, and disarmed.
Group 4
Group 4 supports up to 5 members and the Mouser sends it a SENSOR_
BINARY_REPORT when tripped, reset, armed, and disarmed.
Table 4 - Command Classes