background image

THE JUMPER FOR BACKLIT OPTIONS

Located on the upper-left corner; the two options are for full lights or 

auto lights.

1.  Full backlit – The keypad constantly illuminates.

2.  Auto backlit – The keypad only illuminates during use.

DIRECT ACCESS PROGRAMMING WITH CODE: 8080

If you have forgotten the master code there is still a way to enter 

programming mode.  In order to do this you need to either have an 

egress button installed, or you need to simulate an egress button.  

 

1. First you drop the power to the keypad for one minute. 
2. You then power the keypad back up and 

DURING the one minute 

of beeping

 either push and hold down the egress button that has 

been installed or bridge a wire from the egress in 

(terminal 9) 

to the 

negative ground power 

(terminal 15).

  

3. While you are either pushing the button or with the two terminals 

bridged, press 

 
4. Immediately after pressing the second *the beeping should cease 
and the amber light should hold steady.  At this point you are in 
programming mode.  Immediately upon entering programming mode 
you need to create a new master code.  This is accomplished by 
pressing 

RESET TO FACTORY SETTINGS WITH CODE: 9999

While in programming mode, enter: 

· 

Allow up to 2.5 minutes for the keypad to reset. The yellow LED 

will indicate when the keypad has finished resetting

· 

Note: The current Master Code will not reset

9

0

9

1

9

9

* *

New Master Code

(4-8 digits)

#

#

8 0

0

8

Summary of Contents for dolkpl1kb

Page 1: ...DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL 1 Connection Terminals 2 Basic Wiring Example 3 Quick Start Guide 4 Programming Guide 5 Specifications VIDEO INSTRUCTIONAL...

Page 2: ...ently as a stand alone keypad 1 2 12 24V DC Power Input Terminal 3 8 OUTPUT 1 and OUTPUT 2 Output Relay 1 and 2 N C Normally closed COM Common ground N O Normally open 9 EG IN Egress Input The optiona...

Page 3: ...ignal lasts as long as programmed Entering an output 1 code will deactivate the warning signal Open Door Warning The door will signal a warning if the door is left open for longer than the programmed...

Page 4: ...e lock parallel with the lock power terminals to absorb the back EMF and prevent keypad damage The 1N4004 is not required for AC power To avoid electrostatic discharge from interfering with the keypad...

Page 5: ...shes 5 Power up delay Continuous Beeps Continuous Flashes 6 Output relay activation 1 second Beep 7 Standby 1 flash every second 8 System refreshing Quick flashes for 2 5 minutes 9 Pin already stored...

Page 6: ...ing either push and hold down the egress button that has been installed or bridge a wire from the egress in terminal 9 to the negative ground power terminal 15 3 While you are either pushing the butto...

Page 7: ...equire a new user number Note It is important to docu ment your user numbers because users can be de leted and reassigned new codes for access Delete Access Codes Output 1 2 3 Output Number 05 1 2 or...

Page 8: ...odes the keypad is dis abled for 60 seconds Duress safety setting 60 2 After 10 successive false codes Duress is activated Entering an Access Code Authorization Code will disable the Duress Output Ext...

Page 9: ...ber LED will blink every 2 seconds during functionality Operating Voltage 12V 24V DC Auto adjusting Operating Current 40mA quiescent to 100mA three relays active Operation Temperature 4 F to 158 F Env...

Page 10: ...100mA sink Max for the following outputs a Duress b Alarm c Key Active d Output 3 Door Bell version only e Inter lock Output Contact Ratings Output Relay 1 N C N O dry contacts 5A 24VDC Max Output Rel...

Page 11: ...CULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS T...

Page 12: ...7380 S Eastern Ave Suite 124 320 Las Vegas NV 89123 866 975 0101 866 975 0404 fax www transmittersolutions com...