17
Repair Manual PS-35
Removing the ignition armature
Remove cover.
Remove the starter. See Chap. 06.
Pull off short-circuit cable
2
.
Unscrew 2 screws on ignition armature
3
.
Note:
Be aware of the 2 plastic washers
between the cylinder and the ignition
armature.
Remove ignition armature and high-voltage
cable.
Installing the ignition armature
NOTE:
The high-voltage cable is moulded
onto the ignition system and cannot be
replaced separately.
Insert plastic pieces into the bolt holes on the
cylinder.
Insert the ignition armature, install the short-
circuit cable
1
under the top screw, and screw
in the screws until just before they stop.
Insert the setting gauge
4
(Kapitel 00 Pos.
3) between the ignition armature and the
fylwheel.
Position the
fl
ywheel so that the magnet is
against the armature (gap 0.25 – 0.3 mm).
Press the armature against the gauge towards
the
fl
ywheel and tighten the armature screws
(5 +/-0.5 Nm). Then check the gap again to
make sure it is correct.
Connect short-circuit cable
2
.
Note:
Check the starter pawls on the
fl
ywheel
for easy movement, and clean if necessary.
07 IGNITION SYSTEM
1
2 3
4