14
Repair Manual PS-35
Disassembly
Unscrew three screws
1
.
Remove fan housing
2
.
Remove air guide
3
from fan housing.
Detension the return spring.
Injury hazard! Unscrew screw 5 only after
detensioning the return spring!
Unscrew screw
5
and remove cam
6
and
spring
7
.
Pull off the cable drum
8
.
Carefully turn the fan housing over and pull
the return spring cassette
9
out of the fan
housing.
Caution! The return spring can jump
out of the plastic cassette! Always wear
protective goggles and gloves!
06 STARTER
1
2
5
6
7
3
10
8
9
4
If the spring pops out, put it back into the
plastic housing as shown in the schematic.
Assembly
Note:
If installing a new return spring
cassette, grease it on the spring side.
Carefully insert new return spring cassette
9
.
Lightly grease the surface of the spring and
spring cassette with multipurpose grease
(944.360.000).
Thread in a new starter cable (dia 3.5 mm /
1/8“, length 900 mm / 35.4“) as shown in the
illustration, tie a knot in both ends, and tighten
both knots.
Put on the cable drum
8
and turn it slightly
until the return spring engages.
Insert spring
7
in the cam
6
and place them
together in the cable drum
8
while turning
gently counter-clockwise until they engage.
Insert and tighten screw
5
.
Tension the return spring clockwise. Turn the
return spring about 6 turns with the aid of the
cable, which should be pressed into the gap in
the cable drum.
Place the air guide
3
in the fan housing and
make sure the three recesses
4
engage.
Pull the opening
10
on the fan housing over
the pin on the hood.
Position the fan housing correctly on the saw,
press against it slightly, and pull the starter
handle until the starter catches.
Tighten screws
1
.