Configurable safety system SAFEMASTER PRO - Fieldbus module
50
0265998 / 16.05.19 de / 101A
Module Fieldbus input
Byte offset
Data direction
1
Size
Name
0
In
UINT8
Fieldbus input byte 0
1
In
UINT8
Fieldbus input byte 1
2
In
UINT8
Fieldbus input byte 2
3
In
UINT8
Fieldbus input byte 3
Name
Slot
Instance
Length(byte)
Access type
Fieldbus inputs
01h
01h
4
Set/Get
System I/O
00h
00h
30
Get
Analog data
02h
05h
64
Get
Errors data CPU 0
00h
02h
9
Get
Errors data CPU 1
00h
03h
9
Get
Input diagnostics
00h
04h
32
Get
OSSD diagnostics
00h
05h
32
Get
Project CRC
00h
06h
2
Get
Module System I/O
Byte offset
Data direction
Size
Name
0
Out
UINT8
System status
1
Out
UINT8
Reserved
2
Out
UINT8
Input status byte 0
3
Out
UINT8
Input status byte 1
4
Out
UINT8
Input status byte 2
5
Out
UINT8
Input status byte 3
6
Out
UINT8
Input status byte 4
7
Out
UINT8
Input status byte 5
8
Out
UINT8
Input status byte 6
9
Out
UINT8
Input status byte 7
10
Out
UINT8
Input status byte 8
11
Out
UINT8
Input status byte 9
12
Out
UINT8
Input status byte 10
13
Out
UINT8
Input status byte 11
14
Out
UINT8
Input status byte 12
15
Out
UINT8
Input status byte 13
16
Out
UINT8
Input status byte 14
17
Out
UINT8
Input status byte 15
18
Out
UINT8
Fieldbus input byte 0 feedback
19
Out
UINT8
Fieldbus input byte 1 feedback
20
Out
UINT8
Fieldbus input byte 2 feedback
21
Out
UINT8
Fieldbus input byte 3 feedback
22
Out
UINT8
Probe status byte 0
23
Out
UINT8
Probe status byte 1
24
Out
UINT8
Probe status byte 2
25
Out
UINT8
Probe status byte 3
26
Out
UINT8
OSSD status byte 0
27
Out
UINT8
OSSD status byte 1
28
Out
UINT8
OSSD status byte 2
29
Out
UINT8
OSSD status byte 3
PROFINET (UG 6954)
Process data mapping
Record Data read/write services
1
1
See Acyclic data format
2
Direction from the SAFEMASTER PRO point of view