8
BG 5913.08/_1 _ _ _ / 03.11.20 / 314A
Voltage Supply
Nominal voltage U
N
:
DC 24 V (coming from the basic module
BH5911)
Voltage range:
with max. 5% residual ripple: 0.85 ... 1.15 U
N
Nominal consumption:
max. 60mA
(no load on semiconductor outputs)
Short-circuit protection
of the modules:
internally with PTC
Input
Control voltage
via X1, X2, 48.58:
DC 23 V at U
N
Control voltage
via S12, S14, S22, S24,
S32, S34, S42, S44:
4.5 mA each at U
N
Minimum voltage
on S12, S14, S22, S24,
S32, S34, S42, S44:
DC 16 V
Semiconductor Outputs
Output at terminal 48 and 58: Transistor outputs, plus-connected
Output nominal voltage:
DC 24 V, max. 100 mA constant current,
max. 400 mA for 0.5 s
Internal short circuit, overtemperature, and
overload protection
Reaction Times
(time till reaction of the assigned output):
Typ. NO time with U
N
:
Input modules
BG 5913
Manual start
Automatic start
First start
Restart
Emergency stop
max. 80 ms
max. 1 s
max. 115 ms
Light barriers
max. 80 ms
max. 1 s
max. 115 ms
Safety gates
or simulation:
max. 80 ms
Gate closing:
max. 115 ms
Two-hand control
max. 85 ms
Break time
(reaction time):
Input modules
BG 5913
Emergency stop
max. 33 ms
Light barriers
max. 33 ms
Safety gates
max. 33 ms
Two-hand control
max. 33 ms
General Data
Operating mode:
Continuous operation
Temperature range:
±
0 ...+ 50 °C
At an operating temperature of 50 °C
the modules must be mounted with
a distance of 3 - 5 mm.
Clearance and creepage
distances
rated impulse voltage /
pollution degree:
4 kV / 2 (basis insulation) IEC 60 664-1
EMC:
IEC/EN 61 326-3-1, IEC/EN 62 061
Radio interference
suppression:
Limit value class A
EN 55 011
Remark: This device is designed for industrial ambient conditions.
When used in other environment, it is possible that wire bound or
radiated interference occurs.
Degree of protection
Housing:
IP 20
IEC/EN 60 529
Terminals:
IP 20
IEC/EN 60 529
Housing:
Thermoplastic with V0 behavior
according to UL Subject 94
Vibration resistance:
Amplitude 0.35 mm IEC/EN 60 068-2-6
Frequency 10…55 Hz,
Shock resistance
Acceleration:
10 g
Pulse duration:
16 ms
Number of shocks:
1000 per axis on three axes
Climate resistance:
0 / 050/ 04
IEC/EN 60 068-1
Terminal designation:
EN 50 005
Wire connection:
DIN 46 228-1/-2/-3/-4
Wire fixing:
Box terminal with wire protection, remov-
able terminal strips.
Mounting:
DIN rail
IEC/EN 60 715
Weight:
193 g
Dimensions
Width x height x depth:
22.5 x 84 x 121 mm
BG 5913.08/01MF0
DC 24 V
Article number:
0055530
Technical Data
Technical Data
Standard Type