![DOLD 0055530 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/dold/0055530/0055530_operating-instructions-manual_2516841006.webp)
6
BG 5913.08/_0 _ _ _, BH 5913.08/_0 _ _ _ / 03.11.20 / 314A
In respect of function and settings, the modules BG 5913 and
BH 5913 are completely identical.
• The modules BG 5913 have 8 inputs with one common ground. This is
the ground of the overall system. They are suitable for all applications
in which volt free contacts are used, or where there is a common ground
(e.g. 2-channel light curtains). They need only 8 terminals and thus only
have an overall width of 22.5 mm.
• The modules BH 5913 have 8 completely DC-decoupled inputs. This
allows with setting 1 and 3 (4 lightcurtains) to connect also 4 two-channel
e-stop buttons with long connection wires with static signal potental. Here,
short-circuit monitoring is effected by a certain type of wiring according
to the application examples.
Green LEDs:
on, when all inputs are present and start
button activated.
White LEDs Run1/
Run 2 and outputs
48 and 58:
indicate the current status of the module.
The module is assigned to the start inputs and the safety outputs via the
DIP switches.
The combinations of individual functions are set via the rotary switches.
To prevent accidently adjustments, these elements are covered by a front
plate and are redundant.
plate
M2926_
a
M8941_b
0
2
3
4
7
8
9
0 1 2
5
6
7
9
1
2
3
4
5
6
7
8
output
Mod3
Mod2
Mod1
Base
Mod3
Mod2
Mod1
Base
S1
S2
1
2
3
4
5
6
7
8
start
input
T1
T2
T3
T4
T1
T2
T3
T4
green LED "en 1"
green LED "en 2"
white LED
"run 1"
white LED
"run 2"
off
on
•
Settings to the unit must be performed by skilled personnel while
the unit is disconnected.
•
Before the front cover is removed, antistatic precautions must be
observed.
Note:
When using setting 8 or 9 the user has to indicate clearly on the device
which type of 2-hand function is adjusted (IIIA or IIIC).
Setting of the Modules
Sw.
Function
0
4 Emergency stop 2-channel, autostart
1
4 light curtains category 4, autostart
2
4 Emergency stop 2-channel, manual start
3
4 light curtains category 4, manual start
4
4 safety gates with 2 single contacts
5
2 safety gates with 2 changeover contacts
6
1 safety gate with 2 twin contacts and 1 single contact,
manual start (plastic injection moulding machines) to EN 201
7
1 safety gate with 3 twin contacts, manual start
(plastic injection moulding machines) to EN 201
8
4* two-hand control IIIA acc. to EN 574
9
2* two-hand control IIIC acc. to EN 574
Notes
Indication
Setting of the Module