Dolby
®
Model CP650 Installation Manual
Final Adjustments
7-16
Auditorium Assist
→
Check Auditorium
Set Reference
Auditorium Assist
→
Check Auditorium
Set Reference
(Invalid Reference)
Auditorium Assist
Checking Auditorium:
Left
Press OK to cancel
Auditorium Assist
L:OK C:OK R:OK
Ls: X SW:OK Rs:OK
Bsl:OK Amb:OK Bsr:OK
7.14.3 Auditorium
Sound
Check
The Auditorium Assist sound-check function can be performed at any time.
+
OK
To move the display to the to the
Auditorium
Assist
menu, press the left menu button multiple
times, or press
and hold
the button while rotating
the front-panel knob.
Use the middle menu button to choose Check
Auditorium, then press the OK button to begin the
process.
Note:
The display shows “Invalid Reference” if the CP650 room
equalization settings were changed after reference measurements
were stored. A new set of reference measurements must be
stored.
Auditorium Assist automatically begins the
measurement sequence, beginning with an
auditorium noise floor measurement, then cycling
through all channels. The channel being measured
is displayed.
Note:
The CP650 outputs pink noise at 85dBC for the L, C, and
R channels; 82dBC for each of the surround channels; and
+10dBr for the subwoofer.
Upon completion, channels are listed with “OK”
for pass, or “X” for fail. Any “X” (failure)
indication is logged into the event log.
(See Section 9.3.3.)