![Doka Staxo 100 User Information Download Page 34](http://html.mh-extra.com/html/doka/staxo-100/staxo-100_user-information_2516582034.webp)
34
999804302 - 02/2018
Horizontal assembly
User Information
Load-bearing tower Staxo 100
Lifting into the upright by crane
➤
Check before attaching the lifting chain:
Lifting into the upright
➤
Attach the crane suspension tackle to the frames of
the top section and lift the entire tower into the
upright.
Dismantling
After the tower has been placed back on its side, it can
be dismantled in reverse order.
▪
All the locking springs must be closed =
pushed outwards (to link the frames).
▪
All safety catches must be closed.
▪
All base units must be secured.
NOTICE
Max. extension length of the base units when
the tower is being lifted into the upright: 35
cm!
NOTICE
▪
Erect the load-bearing tower in the vertical
on ground that is statically capable of sup-
porting the load.
▪
If the load-bearing tower is over 6
m high,
back-stay it or combine it with other towers.
When the tower is standing in the upright,
check once again to make sure that all the
safety catches are closed.
98003-214-01
Detaching the crane suspension tackle
near ground level:
This method must not be used for
placing the
tower back on its side
!
Items needed:
▪
3 x Scaffolding tube 48.3mm
(G)
- Minimum length:
Inter-frame space + 1.00
m
▪
6 x normal or swivel couplers, 48mm
(H)
➤
Attach scaffold tubes:
- one between the bottom frames
- two between the top frames
➤
Attach two cables, chains or lifting straps to
the bottom scaffold tube.
➤
Lead the cables, chains or lifting straps
along the outside of the tower and between
the top scaffold tubes.
a ... min. 0.5
m
b ... max. 0.2
m
After the tower has been lifted into the upright,
the cables, chains or lifting straps are
detached by a crewman working from ground
level.
NOTICE
As early as in the planning phase, considera-
tion should also be given to the dismantling
operations (e.g. travelling/towing the load-
bearing tower/unit into the reach of the crane
for safe repositioning or for horizontal on-
ground dismantling)!
98003-218-01
G
H
a
b