14
999239002 - 07/2018
Original Operating Instructions
Framax stripping corner I hydraulic
Hydraulic unit Xclimb 60 V45 50/60Hz
➤
Route the Pair of hydraulic hoses from the stripping
cylinder to the Hydraulic unit Xclimb 60 V45 50/60Hz
and connect the hoses.
Note:
The couplings on the Hydraulic unit Xclimb 60 V45
50/60Hz and the couplings on the pair of hydraulic
hoses for stripping cylinder are colour-coded.
A
'Lift' and 'Lower' hand lever
B
4 pressure-side connections (Lift) Flatface BG2 sleeve (blue)
C
4 pressure-side connections (Lower) Flatface BG2 sleeve (yel-
low)
D
Accessories cover
NOTICE
System pressure controller Xclimb 60 V45
must be installed for the stripping cylinder to
be operated with the Hydraulic unit Xclimb 60
V45 50/60Hz.
Required system pressure: 200
bar
Follow the directions in the 'Hydraulic unit
Xclimb 60 V45 50/60Hz' Operating Instruc-
tions!
9
-20 -
2873
0 02
C
C
B
D
NOTICE
Invariably, only one stripping cylinder can be
connected to and operated with the Hydraulic
unit Xclimb 60 V45 50/60Hz!
Exception:
▪
No-one in the danger zone!
▪
Formwork erecting and stripping operations
are under observation at all times!
A
Hydraulic unit Xclimb 60 V45 50/60Hz
B
Framax stripping cylinder I
C
Pair of hydraulic hoses
(pre-mounted on Framax stripping cylinder I)
D
Pair of hydraulic hoses f. stripp. cyl. 5.00m (optional)
NOTICE
After each formwork erecting or stripping oper-
ation, the pair of hydraulic hoses of the strip-
ping cylinder have to be disconnected from the
hydraulic unit.
D
A
C
B