Original Operating Instructions
Framax stripping corner I hydraulic
15
999239002 - 07/2018
Hydraulic unit SCP V1200 50/60Hz
➤
Route the Pair of hydraulic hoses from the stripping
cylinder to the Hydraulic unit Xclimb SCP V1200
50/60Hz and connect the hoses.
Note:
The couplings on the coupling adapter and the cou-
plings on the pair of hydraulic hoses for stripping cylin-
der are colour-coded.
A
Valve block with motor for pump unit
1
B
Valve block with motor for pump unit
2
C
Manometer for system pressure – Cylinder 1, 2, ... (14)
D
Pre-selector switches for hydraulic circuits 1 - 14
NOTICE
Coupling adapter B Framax stripping cyl. I has
to be used for operating the stripping cylinder
with the Hydraulic unit SCP V1200 50/60Hz.
A
Flatface BG2 sleeve
B
Threaded coupling SKS BG3 (connector)
C
Threaded coupling SKS BG3 (sleeve)
Follow the directions in the 'Hydraulic unit SCP
V1200 50/60Hz' Operating Instructions!
92869-200-01
C
D
A
B
A
C
B
NOTICE
Invariably, only one stripping cylinder can be
operated with the Hydraulic unit SCP V1200
50/60Hz!
Exception:
▪
No-one in the danger zone!
▪
Formwork erecting and stripping operations
are under observation at all times!
A
Hydraulic unit SCP V1200 50/60Hz
B
Framax stripping cylinder I
C
Pair of hydraulic hoses
(pre-mounted on Framax stripping cylinder I)
D
Coupling adapter B Framax stripping cyl. I
E
Pair of hydraulic hoses f. stripp. cyl. 5.00M (optional)
NOTICE
After each formwork erecting or stripping oper-
ation, the pair of hydraulic hoses of the strip-
ping cylinder have to be disconnected from the
hydraulic unit.
A
E
C
B
D
9239-206-03