Manual transducerized BMT series
DOC.60425-05/21
33
Parameter
Description
Auto speed(Yes/NO)
ENABLE provides the safe speed on the torque setting
Fastening stop error (Yes/NO)
DISABLE does not create any NG when the tool stops without fully tightening by
torque up
Reverse lock (Yes/NO)
Driver can be locked in reverse rotation.
LCD button lock
the buttons on the tool can be locked.
F1 lock : used to lock tool F1 button
will lock access to torque and speed manual setting
Auto data output (Yes/NO)
Fastening data output automatically on every event as like run, For/Rev change,
torque up, preset change, etc.
Torque unit
Kgf.cm / Kgf.m / cNm / Nm / ozf.in / lbf.in / lbf.ft
( Whenever the unit is changed, the tool should be reboot again.)
Display enable preset num
Choose the preset which will be selectable by operator on tool display
Screw type
checked : all preset will tighten in CW direction
unchecked : choose for each preset rotation direction
Auto lock (Yes/NO)
Set NO when tool is used stand alone.
Yes always lock the tool. the unlock signal can release the lock Use in job
management by ParaMon-Pro X
Select backup data
Select data to be saved in the internal memory of the tool