Manual transducerized BMT series
DOC.60425-05/21
30
8.4.1 Command details
Command
Description
Data (range)
NOP
No operation
No use
Fastening
Tool start fastening process in forward rotation
Selected Preset is fill in Data field
Preset selection 1 to 15
Loosening
tool start loosening process in reverse rotation
Angle in 0.1 turn up to 999
Select preset#
Select preset # (not mandatory ) Preset can be
selected in data of Fastening command.
Preset selection 1 to 15
Delay
time delay for setting time
1 to 999
Jump
Move to the setting step
2 to 9
Count value = A
Total number “A” to count
1 to 999
Sub if (A)
Subtract 1 from “A” and save the value replacing “A” .
If the value “ A” is not “0”, then move to the next lower
step. If the value “ A” is “0”, then move to 2
nd
lower
step
No use
End
Finish multi-sequence process (mandatory)
No use
8.4.2 Example of Multisequence step program
Step no
Command
Parameter
Description
Step 1
Count Value = A
10
Total counting number is 10.
Step 2
Fastening
1 (Preset #1)
Start fastening with Preset #1 and stop by torque or
angle setting, and move to the next step
Step 3
Loosening
5
Loosen 5 turns and move to the next step
Step 4
Fastening
3 (Preset #3)
Start fastening with Preset #3 and stop by torque or
angle setting, and move to the next step.
Step 5
Sub if (A)
Subtract 1 from “10” and save “9” by replacing “10”.
If the value “ A” is not “0”, then move to the next
lower step. If the value “ A” is “0”, then move to 2
nd
lower step
Step 6
Jump
2
Jump to step no. 2
Step 7
End
End
Step no.2 to Step no. 4 works for a cycle. Total 10 cycles are operated automatically by a start signal.
Any failure or NG on each step, Multi-sequence process stops and provide the alarm signal. Once all steps are
finished successfully, there is FASTENING OK signal output. Every successful fastening in steps provide TORQUE UP
signals.