BG80 USE AND MAINTENANCE BOOKLET
Rev.1 of 23/04/2013 of BG80 uk agg2013 Page 15 of 40
1) Transmission oil level
2) Oil Breather/ Transmission Oil fill
3) Reducer Oil Level
4) Oil Breather/ Transmission Oil fill
4
4
.
.
2
2
.
.
PERIODIC CHECKS/ DAILY CHECKS
Check all moving parts and lubricate regularly (approx. every 50 operating hours) Remove the old, used
lubricant.
Check the stability of the fixing screws on the mixing frame orientation device daily, and those of the hydraulic
cylinder.
If these are damaged or not properly secure, the mixer must be shut down promptly to address the
fault which has been identified.
All screws and nuts must be firmly tightened as indicated in Table in Chapter 8, and must be
checked daily. Any interventions in this regard must be documented.
Carry out daily checks to ensure that none of the rubber parts of the expansion joint are damaged or
torn.
Before starting the mixer each time, check that the electrical network, or rather the power line, meets
the requirements of the provisions in force. Check that the voltage indicated on the motor label
corresponds to the voltage supplied by the electrical network.
4
4
.
.
3
3
.
.
CHECKS TO BE PERFORMED DURING MIXER OPERATION
Check that:
⇒
There are no solid substances blocking the propeller;
⇒
The propeller must always be sufficiently immersed in the product being mixed;
Fig. 4
1
3
4
2