background image

VACUUM INVESTMENT MIXER

ST. LOUIS MINIMIX

INSTRUCTION MANUAL

Summary of Contents for CIMO ST. LOUIS MINIMIX

Page 1: ...VACUUM INVESTMENT MIXER ST LOUIS MINIMIX INSTRUCTION MANUAL ...

Page 2: ...3 INTRODUCTION 4 WARRANTY 4 GENERAL NOTES 4 MACHINE FEATURES 4 OPERATOR SAFETY 4 TRANSPORT 4 TECHNICAL DATA 5 VACUUM PUMP CONNECTION 5 PRELIMINARY OPERATION 5 WATER DOSING TANK AND GRADUATE STICKER SPECIFICATIONS 5 MIXER USE PART 1 6 CONTROL PANEL 6 PARAMETER SETTING 7 MIXER USE PART 2 8 UNIT DRAWING PARTS LIST 9 10 ...

Page 3: ...s vacuum mixers are machines studied and designed for the investment mixing and flask mold filling for the lost wax casting of the jewelry making process The main concept of the St Louis mixing units is the total operativity under vacuum situation Traditionally investment was mixed with water in open air and with this process the final blend result was not really homogeneous and precise so the sur...

Page 4: ...ACUUM PIPE HOSE CONNECTOR VACUUM PUMP MUST BE CONNECTED DIRECTLY TO A SEPARATE 220 VOLTS PLUG PRELIMINARY OPERATIONS Connect the vacuum hose from the rear part of the machine to an external vacuum pump 6 cbm h WHENEVER THE UNIT IS SUPPLIED WITH OUR VACUUM PUMP REMIND TO FILL THE PUMP OIL TANK WITH ITS SPECIFIC OIL BEFORE SWITCHING ON THE PUMP MOTOR Connect the unit to an electrical plug that must ...

Page 5: ...NTITY OF WATER AS MUCH AS WE SEE MARKED ON THE LEVEL LINE VALUE KG 1 7 ON THE DOSING COLUMN STICKER IN ORDER TO HAVE THE EXACT 40 PROPORTION OF WATER FOR THE INVESTMENT LOADED IN THE MIXING CONTAINER Please be informed that the STICKER shows just 40 RATIO IN THE RIGHT SIDE and 38 RATIO IN THE LEFT SIDE Attention in presence of special Platinum Investment powder sometimes the requirement is to add ...

Page 6: ... blade from the clear mixing chamber 2 Place the flask with wax tree on its rubber base on the central part of the lower black plate base 3 of the MIXER Load the investment powder after its weighting into the mixing chamber Check that the pouring valve 4 of mixing chamber is logically closed BE SURE THAT THE MIXING CHAMBER IS DRY Replace the mixing chamber on its original location and insert the m...

Page 7: ...ng procedure is over d WHEN SWITCHING OFF THE MACHINE the parameter will go back again to the initial CIMO value VIBRATION INTENSITY To set the vibration intensity operation possible when vibration is ON or OFF a push button 7 until led is flashing b increase or decrease vibration intensity by pushing 2 or 3 c after 5 seconds from the last pushing on 2 or 3 the setting procedure is over d WHEN SWI...

Page 8: ...PRESETTED WILL BE ZERO THE MOTOR OF THE MIXING BLADE WILL STOP AND A BUZZER WILL SOUND TO WARN THE OPERATOR FOR THE IMMEDIATE POURING OF THE MIXTURE INTO THE FLASK OPEN THE SIDE POURING VALVE KNOB E PULL TOWARD EXTERIOR IN ORDER TO FILL THE FLASK WITH THE MIXTURE CLOSE THE VALVE E WHEN FLASK IS TOTALLY FILLED START VIBRATION BY PUSHING BUTTON 6 AND KEEP THE VIBRATION INTENSITY SMOOTH FOR A COUPLE ...

Page 9: ... 47 MIX92LT2A47 7 MIX92LT2A7 27 MIX92LT2A27 53 MIX92LT2A53 8 MIX92LT2A8 28 MIX92LT2A28 59 MIX92LT2A59 9 MIX92LT2A9 29 MIX92LT2A29 60 MIX92LT2A60 10 MIX92LT2A10 30 MIX92LT2A30 61 MIX92LT2A61 11 MIX92LT2A11 31 MIX92LT2A31 62 MIX92LT2A62 12 MIX92LT2A12 32 MIX92LT2A32 63 MIX92LT2A63 13 MIX92LT2A13 33 MIX92LT2A33 14 MIX92LT2A14 34 MIX92LT2A34 15 MIX92LT2A15 35 MIX92LT2A35 16 MIX92LT2A16 36 MIX92LT2A36 ...

Page 10: ...MIX92LT2B7 30 MIX92LT2B30 8 MIX92LT2B8 31 MIX92LT2B31 9 MIX92LT2B9 32 MIX92LT2B32 10 MIX92LT2B10 33 MIX92LT2B33 11 MIX92LT2B11 34 MIX92LT2B34 12 MIX92LT2B12 35 MIX92LT2B35 13 MIX92LT2B13 36 MIX92LT2B36 14 MIX92LT2B14 37 MIX92LT2B37 15 MIX92LT2B15 38 MIX92LT2B38 16 MIX92LT2B16 40 MIX92LT2B40 17 MIX92LT2B17 41 MIX92LT2B41 18 MIX92LT2B18 42 MIX92LT2B42 19 MIX92LT2B19 43 MIX92LT2B43 20 MIX92LT2B20 44 ...

Reviews: