TECHNICAL DATA
VOLTAGE: 220 V. - 50/60 HZ. SINGLEPHASE – CONSUMPTION: KW. 0, 8
PROTECTION FUSE: 4 AMP.
MAX INVESTMENT CAPACITY : GRAMS 800 - MAX FLASK SIZE: DIAMETER 100 mm. X 120 mm. HIGHT
VACUUM PUMP CONNECTION
THE MIXER MUST OPERATES WITH A VACUUM PUMP OF MINIMUM CAPACITY 6 CBM/HOUR.
THE VACUUM PUMP IS SUPPLIED SEPARATELY AS OPTIONAL ACCESSORY.
ON THE REAR PART OF THE MACHINE BASE FIND THE VACUUM PIPE HOSE CONNECTOR.
VACUUM PUMP MUST BE CONNECTED DIRECTLY TO A SEPARATE 220 VOLTS PLUG.
PRELIMINARY OPERATIONS
Connect the vacuum hose from the rear part of the machine to an external vacuum pump (6 cbm/h.).
WHENEVER THE UNIT IS SUPPLIED WITH OUR VACUUM PUMP,
REMIND TO FILL THE PUMP OIL TANK WITH ITS SPECIFIC OIL
BEFORE SWITCHING ON THE PUMP MOTOR.
Connect the unit to an electrical plug that must have ground.
Fill the open dosing tank ( located on the right part of the motor column of the unit )
with clean water ( temperature between 20° and 24° C. ) correctly to the top level line
of the sticker indicating the water proportion quantity. ( ratio: 1 kg. powder = 400 cc. water )