TDR9000
™
Circuit Breaker Test System User’s Guide
72A-1898 Rev. A 11/01
A-73
Monday
, November 26, 2001 1:09 pm
Main Contact
Timing – Reclose
Parameters include:
Minimum
The minimum time from trip initiation to Main
Contact make
Maximum
The maximum time from trip initiation to Main
Contact make.
Figure A.85 shows how contact timing occurs on a module-by-module
level.
Module (A)
The maximum allowable difference in time
between the Trip initiation and the closing of the
two Main Contacts in any module.
Phase (B)
The maximum allowable difference in time
between the Trip initiation and the closing of any
two Main Contacts in any phase.
Breaker (C)
The maximum allowable difference in time
between the Trip initiation and the closing of any
two Main Contacts in a circuit breaker.
Figure A.85 Main Contact Timing – Reclose
Module #1
Module #1
Module #2
Module #1
Module #2
Module #2
#!
#2
#3
#4
#!
#2
#3
#4
Contact #1
Contact #2
Contact #3
Contact #4
Main Contact reopening time
C
0
A
0
C
0
20
40
60
80
Time (ms)
First Switch to Last Switch
B
A
0
B
Summary of Contents for TDR9000
Page 26: ...xxii 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 50: ...Step 5 Saving Test Results 1 24 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 98: ...3 28 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 200: ...Disconnecting After the Test 4 102 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 362: ...B 34 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 388: ...D 6 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 392: ...E 4 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 394: ...F 2 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 442: ...I 32 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Page 454: ...I 12 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...