![background image](http://html1.mh-extra.com/html/dmx4all/dmx-relais-analog-interface-1/dmx-relais-analog-interface-1_user-manual_2514398005.webp)
DMX Relais/Analog Interface 1
5
LED-Display-Codes
The integrated green LED is a multi functional display.
During the normal operation the LED lights permanently. In this case the device is
working.
Furthermore, the LED shows the current status. In this case the LED lights up in
short pitches and then is missing for longer time.
The number of the flashing lights is equal to the event number:
Status-
Number
Error
Description
1
No DMX
There is no DMX-Signal deteced
2
Addressing error
Please check the adjusted DMX address
4
Settings stored
The settings are stored
DMX-Addressing
The start address is adjustable about switch 1-9.
Thereby, switch 1 has the valency 2
0
(=1), switch 2 the valency 2
1
(=2) and so on, up
to switch 9 with the valency 2
8
(=256).
The sum of the switches showing ON is equal to the start address.
Address Switch
Address Switch
1
...
...
2
508
3
509
4
510
5
511