background image

 

 

 
 
 
 
 
 

DMX Relais/Analog Interface 1 

 
 
 
 
 
 

User Manual

 

 

 

 

 

Summary of Contents for DMX Relais/Analog Interface 1

Page 1: ...DMX Relais Analog Interface 1 User Manual...

Page 2: ...or voltages from 12V up to 24V The DMX Relais Analog Interface 1 runs with supply voltages from 12 up to 24V direct voltage DMX FAIL Function An adjustable DMX FAIL Function offers the option to hold...

Page 3: ...open NO max 8A 250V 165A 20ms Power up current peak 1 analog signal 0 10V or 1 10V Operation modes Relay Analog 8Bit 0 10V Relay Analog 8Bit 1 10V Relay Analog 10Bit 0 10V Relay Analog 10Bit 1 10V Rel...

Page 4: ...DMX Relais Analog Interface 1 4 Connection DMX Relais Analog Interface 1 GND DMX DMX ADDRESS DMX OUT ANALOG 12 24V GND 0V max 10mA POWER ANALOG OUT 12 24V DMX IN...

Page 5: ...number of the flashing lights is equal to the event number Status Number Error Description 1 No DMX There is no DMX Signal deteced 2 Addressing error Please check the adjusted DMX address 4 Settings s...

Page 6: ...ghts up 4x to confirm the takeover Adjust the DMX address via switches 1 9 Switch 1 OFF Relay Analog Relay and analog output are controlled with separate DMX channels Relay switches at DMX VALUE 127 S...

Page 7: ...ality 2 Relay and analog output are controlled each with one DMX channel The analog output has an 8 Bit resolution and an output voltage of 1 10V DMX Channel DMX Value Function 1 0 127 Relay OFF 128 2...

Page 8: ...ay Analog 8Bit 0 10V Personality 5 Relay and analog output are controlled with the same DMX channel The analog output has an 8 Bit resolution and an output voltage of 0 10V DMX Channel DMX Value Funct...

Page 9: ...log output 0 10V HIGH DMX channel 1 and 2 0 Relay OFF DMX channel 1 or 2 0 Relay ON 2 0 255 Analog output 0 10V LOW Relay Analog 10Bit 1 10V Personality 8 Relay and analog output are controlled with t...

Page 10: ...settings Switch 8 ON DMX HOLD active Switch 8 OFF DMX HOLD not active If HOLD is switched on the last received DMX values are remained in case of a DMX signal failure If HOLD is switched off the DMX...

Page 11: ...he address switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUT...

Page 12: ...is Analog Interface 1 12 Manufacturer depending RDM control commands SERIAL_NUMBER PID 0xD400 Outputs a text description ASCII Text of the device serial number GET Send PDL 0 Receive PDL 21 21 Byte AS...

Page 13: ...turn off power supply Set DIP switch 1 up to 10 to ON Turn on the device turn on power supply The LED lights up 20x during ca 3 seconds While the LED lights up set DIP switch 10 to OFF Now the Factory...

Page 14: ...DMX Relais Analog Interface 1 14 Dimensions all details in mm...

Page 15: ...DMX Relais Analog Interface 1 15 Accessory Top hat rail mounting 350 Power supply 12V 20W...

Page 16: ...directive 2014 30 EU is necessary Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with applicable legal reg...

Page 17: ...g To e probability of a failure a redundant system structure is necessary For the installation of the board the board must be connected and adjusted to foreign components according to the device paper...

Page 18: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...

Reviews: