Page 2: ...ey Lock 7 Menu Guide 8 DMX Address 9 Display Switch Off 9 DMX Fail Behavior 10 Operation Modes 11 Personality 1 Hysteresis 127 128 12 Personality 2 Hysteresis 0 1 13 Personality 3 Hysteresis 100 150 1...

Page 3: ...s the option to hold the current state HOLD or to adopt a predefined value if the DMX signal fails RDM support The DMX RELAIS 8 INRUSH allows the configuration via RDM or DMX Touch Control The DMX REL...

Page 4: ...usive Monostable 1Second Output 8 potential free switching output closer NO each max 8A 165A 20ms peak switch on current Display 7 segment display RGB LED TOUCH Control 3 touch buttons Connections Scr...

Page 5: ...DMX RELAIS 8 INRUSH 5 Connection DMX RELAIS 8INRUSH GND V DMX DMX GND DMX OUT 1 2 3 4 5 6 7 8 POWER 12 24V DMX IN POWER POWER Switch contact each max 8A 165A 20ms peak switch on current...

Page 6: ...The integrated RGB status display is a multifunction display Off Power supply not connected Display is switched off RED flashes No DMX signal detected GREEN Device ready for use GREEN flashes Device s...

Page 7: ...no button is pressed for ca 15 seconds the key lock starts automatically and the set DMX start address is showed The activated key lock is displayed via a lighting dot right below in the display To r...

Page 8: ...llowed by the set value The letter abbreviations are assigned as follows A DMX Start address PE Personality F Fail Mode oFF AutoOff Time The menu navigation is shown as follows Start A001 MENU PE01 F...

Page 9: ...tched off The shutdown can occur manually or automatically Manually it takes place via the RDM parameter DISPLAY_LEVEL To activate the automatic shutdown the RDM parameter DISPLAY_AUTO_OFF Is to selec...

Page 10: ...buttons or the value is set in a range of 0 and 255 If or is pressed held the value increases or decreases automatically until the button is pressed If the maximum value of 255 is reached the hold fun...

Page 11: ...ousie Control Personality 5 Monostable 1Second Impulse The number of the needed DMX channels and their assignment as well as the way of controlling the outputs depends on the Personality The Personali...

Page 12: ...t the relay is switched on when the DMX value is 128 or greater DMX Channel DMX Value Function 1 0 127 Output 1 OFF 128 255 Output 1 ON 2 0 127 Output 2 OFF 128 255 Output 2 ON 3 0 127 Output 3 OFF 12...

Page 13: ...lue is 0 and that the relay is switched on when the DMX value is 1 or greater DMX Channel DMX Value Function 1 0 Output 1 OFF 1 255 Output 1 ON 2 0 Output 2 OFF 1 255 Output 2 ON 3 0 Output 3 OFF 1 25...

Page 14: ...t 1 OFF 101 149 Output 1 NO ACTION 150 255 Output 1 ON 2 0 100 Output 2 OFF 101 149 Output 2 NO ACTION 150 255 Output 2 ON 3 0 100 Output 3 OFF 101 149 Output 3 NO ACTION 150 255 Output 3 ON 4 0 100 O...

Page 15: ...8 cannot be switched on at the same time DMX Channel DMX Value Function 1 0 127 Output 1 OFF 128 255 Output 1 ON if output 2 OFF 2 0 127 Output 2 OFF 128 255 Output 2 ON if output 1 OFF 3 0 127 Outpu...

Page 16: ...g pulse DMX Channel DMX Value Function 1 0 127 Output 1 OFF 128 255 Output 1 1x 1 second ON 2 0 127 Output 2 OFF 128 255 Output 2 1x 1 second ON 3 0 127 Output 3 OFF 128 255 Output 3 1x 1 second ON 4...

Page 17: ...orts the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUTE E1 20 DEVICE_INFO E1 20 SUPPORTED_PARAMETERS E1 20...

Page 18: ...NUMBER PID 0xD400 Outputs a text description ASCII Text of the device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Text DISPLAY_AUTO_OFF PID 0xD401 Sets the time after which the display i...

Page 19: ...Byte IDENTIFY_MODE_ID SET Send PDL 1 1 Byte IDENTIFY_MODE_ID Receive PDL 0 IDENTIFY_MODE_ID Function 0 FULL Identify All relays switch simultaneously ON OFF and the status LED flashes 1 LOUD Identify...

Page 20: ...de tab with a screw driver Turn the address switches 1 up to 10 on ON Turn on the device Turn on power supply Now the LED next to the address switch flashes within ca 3 seconds for 20x During the LED...

Page 21: ...DMX RELAIS 8 INRUSH 21 Dimensions All details in mm 60mm 90mm 105mm...

Page 22: ...DMX RELAIS 8 INRUSH 22 Accessoires Power supply 12V...

Page 23: ...EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with applic...

Page 24: ...he board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it...

Page 25: ...d using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that...

Reviews: