DMX FAIL Action
In case of DMX lost (DMX-Fail) the DMX-LED-Dimmer XS3 is able to hold the LED
outputs on the last value, to use a predefined DMX value or to execute a user-
defined program.
The DMX Fail action is to set via the RDM-Parameter DMX_FAIL_MODE.
After voltage drop the held values are not restored by the HOLD function.
In this case, the values are set to 0 (OFF) or a user-defined program is
executed.