XR150FC/XR550FC Series Installation Guide
Digital Monitoring Products
3
IntroductIon
System Components
3.1
Wiring Diagram
The diagram shows some of the accessory modules you can connect for use in various applications. A brief
description of each module follows in section 3.4.
AC
1
2
3
4
5
6
7
8
10
11 12 13 14
15 16
17
18 19
9
20
21 22
23
24 25 26 27 28
+B
BELL GND
SMK GND
RED YEL GRN BLK
Z1
Z2 Z3
Z4 Z5
Z6 Z7
Z8 Z9+ Z9– Z10+ Z10–
AC
–B
GND
GND
GND
GND
XR550FC Series
Panel
¼"
Smoke
Detector
3.3k Ohm 3.3k Ohm 3.3k Ohm 3.3k Ohm
1k Ohm
AC Wiring must be in conduit and exit
out the left side of the enclosure.
Wiring on terminals 5 through 22 must
exit right and maintain 1/4" separation
from the AC and battery positive wiring.
Form C Relays (J2)
Output Color Code–Model 431 Harness
Output 2 N/O Orange/White
Output 2 Com White/Gray
Output 2 N/C Violet/White
Output 1 N/O Orange
Output 1 Com Gray
Output 1 N/C Violet
Annunciator Outputs (J11)
Output Color Code
Output 3
Red
Output 4
Yellow
Output 5
Green
Output 6
Black
Front
Tamper
Rear
Tamper
s
RED
BLACK
Bell
Zone
1
Zone
2
Zone
3
Zone
4
Zone
5
Zone
6
Zone
7
Zone
8
3.3k
Ohm
Resistor
3.3k
Ohm
Resistor
Zone Expander
Model 715
7mA @ 12 VDC
Models 715-8, 715-16
20mA @ 12 VDC
1k Ohm
s
= Supervised Circuit
Zone
9
Zone
10
22
gauge
minimum
22
gauge
minimum
22
gauge
minimum
22
gauge
minimum
RED
YELLOW
GREEN
BLACK
1k Ohm 1k Ohm 1k Ohm
Zone Expander
Model 714
7mA @ 12 VDC
Models 714-8, 714-16
20mA @ 12 VDC
RED
YELLOW
GREEN
BLACK
RED
s
s
s
s
s
s
s s
s
s
S
S
S
S
S
S
S
S
S
S
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
1k
Ohm
S
S
S S
S S
S S
S S
1k Ohm
Zone Expander
(up to 8 zones)
Model 712-8
19mA @ 12
VDC
S S
Zone
Expander
Model 711
7mA @ 12
VDC
1.5k
Ohm
s
Ground
s
J3
Phone Line
J16
Reset
J4
Tamper
Battery
Start
Power
LED
Activity LED
J1
Ethernet
Outputs 3-6
J11
J10
K6
K7
Output 1
Output 2
Out1
Out2
J2
Link LED
J24
Cell Module
J18
Load
J7
s
s
PROG
J8
J14
J9
J15
J13
J17
J19
J6
LX
K
DMP Transformer
16 VAC 56 VA
Class 2 Wire-in.
Secondary Power Supply
1.0 Amps Max. charging
current. Use only 12 VDC
rechargeable batteries.
DMP Models 364, 365, 366,
368, or 369. Replace
batteries every 3 to 5 years.
Bell
12 VDC nominal
Minimum cutoff time is
5 minutes.
.7 Amp Max
Keypads
Model 630F
60mA at 8 to 14.5 VDC
Bell cutoff time
range is 5 to 99
minutes marchtime
and non-coded.
All circuits are inherent Power
Limited except the red battery wire
and AC terminal.
NFPA 72
This equipment should be installed
in accordance with Chapter 11 of
the National Fire Alarm Code,
ANSI/NFPA 72-2002, (National Fire
Protection Association,
Batterymarch Park, Quincy, MA
02269). Printed information
describing proper installation,
operation, testing, maintenance,
evacuation planning, and repair
service is to be provided with this
equipment.
Use UL Listed Power
Supervision Relay
rated at 12 VDC.
POWER
TROUBLE
ALARM
COMMAND
1
2
3
4
5
6
7
8
9
0
ABC
DEF
GHI
JKL
MNO
PQR
STU
VWX
YX
ENABLE
SILENCE
RESET
TEST
DRILL
Fire Command Center
WARNING: Incorrect
connections may cause
damage to the unit.
CAUTION:
DO NOT USE LOOPED WIRE
UNDER TERMINALS. BREAK WIRE RUN TO
PROVIDE SUPERVISION OF CONNECTIONS.
Auxiliary Power
Total current combined from
terminals 7, 11, 25, 27, and
LX500-LX900
.5 Amp Max
Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
10K Ohm - DMP Model 308
Cold Water
Pipe Earth
Ground
Heat detectors, pull
stations, or any other
contact devices listed
for Fire Protective
Signaling can be
connected to zones
9 and 10.
Zones 9 and 10 and
Model 715 compatibility
identifier: A
Maximum operating
range: 9.8 VDC to
14.0 VDC.
Class B (Style A).
Zones 9, 10, and all
expanded zones are
suitable for Class B (as
applicable for the
initiating and signaling
line circuits per ANSI/UL
864 Table 48.2 or 48.3).
Installation limits under
local Authority Having
Jurisdiction (AHJ).
Using verification delays
on zones 9 and 10 is
optional. Use the
delays marked on the
smoke detectors or
the smoke detector
installation wiring
diagram.
WARNING
THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION
FEATURE THAT RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM
THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS
SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER
SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
Verification
Zones
______
Control Unit
Delay
13.6 sec.
Smoke
Model
______
Detector
Delay
____sec.
Figure 1: XR150FC/XR550FC Series Wiring Diagram
3.2
Lightning Protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on XR150FC/XR550FC
Series input and output circuits. Additional surge protection is available by installing the DMP 370 or 370RJ Lightning
Suppressors.
3.3
Network Protection
The Model 270 Network Transient Suppression Module protects the XR150FC/XR550FC panel from surges on the
Ethernet (J1) port.