XR150FC/XR550FC Series Installation Guide
Digital Monitoring Products
11
InstallatIon
Standby Battery Power Calculations
Standby Current
Alarm Current
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
Qty _______
Qty _______
x
x
25mA
___mA
______
______
Qty _______
Qty _______
x
x
25mA
___mA
______
______
738A Ademco Wireless Interface Module
Qty _______ x
75mA ______
Qty _______ x
75mA ______
710 Bus Splitter/Repeater Module
Qty _______ x
32mA
______
Qty _______ x
32mA
______
711 Zone Expansion Module
Active Zone (EOL Installed)
Qty _______
Qty _______
x
x
11mA
1.6mA
______
______
Qty _______
Qty _______
x
x
11mA
2mA*
______
______
714 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
7mA
1.6mA
______
______
Qty _______
Qty _______
x
x
7mA
2mA*
______
______
712-8 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
17mA
1.6mA
______
______
Qty _______
Qty _______
x
x
17mA
2mA*
______
______
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
20mA
1.6mA
______
______
Qty _______
Qty _______
x
x
20mA
2mA*
______
______
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
7mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
7mA
30mA
*
.1mA
______
______
______
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
20mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
20mA
30mA
*
.1mA
______
______
______
716 Output Expansion Module
Active Form C Relays
Qty _______ x
13mA
______
Qty _______
Qty _______
x
x
13mA
12mA
______
______
717 Graphic Annunciator Module
Annunciator Outputs
Qty _______ x
10mA ______
Qty _______
Qty _______
x
x
10mA
1mA
______
______
521LX, 521LXT Smoke Detectors
Qty _______ x
8.8mA
______
Qty _______ x
28mA
* ______
2W-BLX, 2WT-BLX Smoke Detectors
Qty _______ x
11mA ______
Qty _______ x
31mA
* ______
COSMOD2W Module
Qty _______ x
45mA
______
Qty _______ x
174mA*#
______
COSMO-2W Smoke and CO Detectors
Qty _______ x
1mA ______
Qty _______ x
50mA*#
______
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and LX-Bus Modules
______mA
______mA
Sub-Totals this page
Sub-Total Standby
______mA
Sub-Total Alarm
______mA
Sub-Totals from previous page
Sub-Total Standby
______mA
Sub-Total Alarm
______mA
*Based on 10% of active zones in alarm
Total Standby ______mA
Total Alarm ______mA
# For systems that are not central station monitored, multiply alarm current by 12.
Total Standby______mA x number of Standby Hours needed
Total Alarm
______ =
______mA
Total
_______mA-hours
+_______mA-hours
_______mA-hours
X .001
= _______Amp-hrs
Required
Refer to section 6.9 for standby battery selection.