8
LCD Keypad Installation Guide
Programming Keypad Options
Kpd Kpd
Opt diag
StOp
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under
KPD OPT.
CUrrent Keypad
addreSS:
01
Keypad Address
Set the keypad address from 01 to 08 with the XT30, XT50,
XR100, and XR150. Set the keypad address from 01 to 16
with the XR500, XR350, and XR550. The factory default
address is set at 01. To change the current address, press any
Select key and enter the new address. It is not necessary to
enter a leading zero for addresses 01 to 09.
Keypad MOde:
*SUp
UnSUp
Keypad Mode
Configure the keypad for either Supervised or Unsupervised
operation. Keypads with zones connected to them must be
supervised and cannot share addresses with other keypads.
Unsupervised keypads can operate with other unsupervised
keypads sharing the same address. Zones cannot be used on
unsupervised keypads. To change the current setting, press
the Select key under SUP or UNSUP. An asterisk appears next
to the selected option.
Note:
Unsupervised addresses cannot be used when Device
Fail Output has a programmed value other than zero.
deFaULt Keypad
MSg:
Default Keypad Message
Enter a custom message of up to 16 characters to appear on
the keypad display top line whenever that line is not used for
any other purpose. Press any Select key to clear the current
message and enter a new custom display.
arM paniC KeyS:
*pn *eM *Fi
Arm Panic Keys
Use this option to configure the top row Select keys as
2-button Panic keys. To enable or disable a Panic, press the
Select key under the appropriate display: PN (Panic), EM
(Emergency), and FI (Fire). Once the panic is enabled, an
asterisk displays next to the description. Refer to the Panic
Key Options section earlier in this document.
7/0 paniC
enabLe: nO yeS
7/0 Panic
Select YES to configure the 7 and 0 keys as a 2-button Panic
keys. To disable the option, select NO. Default is NO. Refer
to the Panic Key Options section earlier in this document.
aCtiVate zOne 2
ShUnt: nO yeS
Zone 2 Shunt (7573/7573A only)
Select YES to enable the Soft-Shunt™ option on zone 2
as described earlier in this document. This zone provides
the Soft-Shunt™ for door contacts. This zone must be
programmed into the panel.