background image

Name

Phone

Address

City

State

Zip

2841 E. Industrial Drive   Springfield, MO 65802-6310   800-641-4282

Digital Monitoring Products

*No Bell Circuit or LED alarm status

**Bell Circuit and LED alarm status

Programming Option Table

PROGRAMMING INFORMATION

For 740, 741, and 743 SC Series Keypad

Bus address

_ _   (00 to 99)

LX-Bus Comm.

   _   (0,1, or 4)

Bell Cutoff

_ _   (00 to 15 min.)

Exit Delay

_ _   (00 to 99 sec.)

Entry Delay

_ _   (00 to 99 sec.)

Zone #

Type

Description

Zone 1

Perimeter Entry/Exit

Zone 2

Perimeter Instant

Zone 3

Interior Instant

Zone 4

Fire or Panic

Alarms on internal speaker

❑ 

 NO

❑ 

 YES

Panic Keys

❑ 

 NO

❑ 

 YES

Zone 4 Operation (Panic or Fire)

_   (1, 2, or 3)

Relay Operation (741 & 743 only)

_   (1 to 3)

Battery Test

❑  

NO

❑ 

 YES

Option #

740

741

743

Keys Pressed

Description

Range

Default

1

X

X

X

SPECIAL,0,1

Programming Initialization

0=No, 1=Yes

0

2

X

X

X

SPECIAL, 0,2

Clear User Codes

0=No, 1=Yes

0

3

X

X

X

SPECIAL,0,3

Bus Address

00-99

00

4

X

X

X

SPECIAL,0,4

LX-Bus Communication Style

0=None, 1=711, 4=714

1

5

SPECIAL,0,5

For future use

6

SPECIAL,0,6

For future use

7

X

X

X

SPECIAL,0,7

Bell Cutoff Time

00-15 Minutes

05

8

X

X

X

SPECIAL,0,8

Exit Delay Time

00-99 Seconds

60

9

X

X

X

SPECIAL,0,9

Entry Delay Time

00-99 Seconds

30

10

X

X

X

SPECIAL,1,0

Alarms on Internal Speaker

0=No, 1=Yes

1

11

X

X

X

SPECIAL,1,1

Panic Keys Enabled

0=No, 1=Yes

0

12

X

X

X

SPECIAL,1,2

Zone 4 Operation (Panic or Fire)

1=Panic*, 2=Panic**, 3=Fire

1

13

N/A

X

X

SPECIAL,1,3

Relay Operation

1=Alarm, 2=Access, 3=Sensor Reset

1

14

N/A

X

X

SPECIAL,1,4

Battery Test Enabled

0=No, 1=Yes

0

15

SPECIAL,1,5

For future use

99

X

X

X

SPECIAL,9,9

Set Programming Access Code

0000-9999

0000

00

X

X

X

SPECIAL,0,0

Exit Programmer Mode

00

N/A

Summary of Contents for SC Series

Page 1: ... magnetic locks Alarm Relay connect to an external annunciator Sensor Reset connect to power of 4 wire smoke detector The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC LT 0393 7 98 INSTALLATION PROGRAMMING 740 741 and 743 SC Series LED Keypads 2841 E Industrial Drive Springfield MO 65802 6310 800 641 4282 Wiegand Input A Wiegand style card reader may be at...

Page 2: ...escriptions on the front of the card before inserting the card into the keypad Gently twist while pulling halves apart Repeat at other opening Surface and backbox mounting holes Surface and backbox mounting holes Surface and backbox mounting holes Keypad Mounting Template Installing the keypad The SC Series keypads each use the same plastic housing and are designed to easily install on any 4 squar...

Page 3: ...43 keypads and determines the keypad relay output operation Enter 1 for alarm relay 2 for door access relay operation or 3 for sensor reset When configured as alarm relay the relay turns on anytime the Bell Output turns on Option 14 Battery Test Enter 1 when installing a 741 or 743 keypad and battery backup voltage monitoring is desired Low battery is detected at 11 9 VDC Option 15 This option res...

Page 4: ...ription Range Default 1 X X X SPECIAL 0 1 Programming Initialization 0 No 1 Yes 0 2 X X X SPECIAL 0 2 Clear User Codes 0 No 1 Yes 0 3 X X X SPECIAL 0 3 Bus Address 00 99 00 4 X X X SPECIAL 0 4 LX Bus Communication Style 0 None 1 711 4 714 1 5 SPECIAL 0 5 For future use 6 SPECIAL 0 6 For future use 7 X X X SPECIAL 0 7 Bell Cutoff Time 00 15 Minutes 05 8 X X X SPECIAL 0 8 Exit Delay Time 00 99 Secon...

Reviews: