Vandal Resistant Piezo Keypads  

CM-626S and CM-634 Series 

 

Installation Instructions 

 

MOUNTING 

 
 

Drill

 mounting holes using template provided 

 

Connect

 keypad using wiring 

 

WIRING DESCRIPTION 

 

BLUE / BROWN 

12 to 24VDC  

 (BROWN is Positive) 

GREY   

 

Common  

 

RED 

 

 

N.O.(default) or N.C., 

2A,.. Programmable. 

WHITE / PINK 

Interior switch input (Dry 

contact only!) 

GREEN  

 

Earth 

NOTE: 

1.  For inductive loads such as electric strikes and 

electromagnetic locks, the enclosed 

varistor 

must be connected in parallel with the load, at 
the load terminals and not in the keypad. 

2.  Ensure power supply is of correct rating, taking 

into account the current requirements of the 
locking items and accessories. 

3.  The interior switch input is via a dry contact 

between the White & Orange wires. The door 
strike will activate for the time programmed into 
the system.  This input is disabled during 
programming and latch mode. 
 

 
 
 
 
 
 
 

LED EXPLAINATION 

 
GREEN LED:  Relay activated 

RED LED 

Normal Operation 

3 sec. ON = Wrong Code Entry    

Programming Mode: 

 

         Fast flashing = Programming                
 

                    functions 

 

 

         

 

 Slow flashing = Programming      

                                               

  

stand-by 

 

 

 Very Fast flashing = Erasing all   

 

                                               user codes 

 
 

TESTING THE KEYPAD  

 
Apply power to the keypad: 

 

 

The keypad’s buzzer will sound briefly, the red LED will 
illuminate briefly. Initialisation is now complete, with a 
default master code of 1-2-3-4 and 5-second open door. 
 
Enter the master code:  [1 2 3 4 #]: 
The Door Relay changes its contacts for 5 sec.  The 
Green LED will light up for 5 seconds. 
Repeat this step 2 or 3 times. 
If the master code is entered incorrectly, the Red LED 
illuminates for 3 seconds. 
Re-enter the Code as soon as the Red LED goes OFF. 
 
 
 
 
 
 
 

 

PROGRAMMING THE KEYPAD 

 
Enter **1 2 3 4** 

 

 

 

 

The keypad enters programming mode, the red LED 
flashes. 
If no further information is added, the unit will revert to 
normal operation after a 15 second delay. 
To exit programming press # 
 

There are six programming options: 

1.  Set new master code 
2.  Set new user code 
3.  Erase a user code 
4.  Erase all user codes 
5.  Set door open time (1-99 seconds) 
6.  Set output to latch option 
 
 
 
 

Do not insert security plugs into fixing 
holes until all installation and testing has 
been completed!! These items require 
drilling out and cannot be re-fitted. 

 

It is good practice to change the factory 
default master code. There is no way to 
recover the new Master Code, if it is lost or 
forgotten however, the unit can be easily reset 
to Factory Presets and re-programmed again. 

 

Summary of Contents for CM-626S Series

Page 1: ...ser codes TESTING THE KEYPAD Apply power to the keypad The keypad s buzzer will sound briefly the red LED will illuminate briefly Initialisation is now complete with a default master code of 1 2 3 4 and 5 second open door Enter the master code 1 2 3 4 The Door Relay changes its contacts for 5 sec The Green LED will light up for 5 seconds Repeat this step 2 or 3 times If the master code is entered ...

Page 2: ...ogramming mode the red LED flashes Enter 3 The red LED illuminates for 2 seconds and then flashes Enter address to be removed le 001 001 200 accepted Enter The red LED illuminates for 2 seconds and then flashes Enter address to be removed again le 001 001 200 accepted Enter The red LED illuminates flashes the code is removed Enter To exit programming 4 To remove all user codes Enter master code Th...

Page 3: ...ss the reset button on the rear of keypad The red LED illuminates for 2 seconds and then flashes Enter 1 2 3 4 The red LED illuminates for 2 seconds and a continuous tone is heard Press the reset button on the rear of the keypad Enter The red LED illuminates for 2 seconds and then flashes Enter The relay is set to open the door for 5 seconds Master code 1 2 3 4 User code 5 6 7 8 9 0 For greater se...

Page 4: ...Call us toll free at 1 877 226 3369 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 www camdencontrols com Toll Free 1 877 226 3369 File CM 626S and CM 634 Series Rev2 Revised December 30 2014 Part No 40 82B036 ...

Reviews: