background image

2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282

SC Series Keypad Installation

3

Option 1 Program Initialization

This option sets all programing options except Programming
Access Code to their factory default values. Press 1 and hold for
two seconds until keypad beeps once.

Option 2 Clearing User Codes

To clear all user codes from the memory, press 1 and hold for two
seconds until keypad beeps once. All user codes are now cleared
and user code 0099 (99 CMD) is placed in user number eight.

Option 3 Bus address

Set the bus address from 00 to 99. It is not necessary to enter a
leading zero for addresses 01 to 09.

Option 4 LX-Bus Communication

This option allows communication of local zone conditions to a
supervising XR200 or XR200-485. Enter 0 (none) when zone
conditions are not sent to the supervising panel. Enter 1 (711
style) when all four local zone conditions are combined as one
zone on the LX-Bus. Enter 4 (714 style) when each local zone
condition is individually sent on four consecutive addresses of the
LX-Bus.

Option 5

This option reserved for future use.

Option 6

This option reserved for future use.

Option 7 Bell Cutoff Time

This option selects the maximum time in minutes (0-15) that the
Bell Output will allow a bell or siren to sound. If the Bell Output is
manually silenced or the system is disarmed, the cutoff time is
reset. Enter 0 to provide continuous bell output with no cutoff.

Options 8, and 9 Exit and Entry Delays

These options set the delay time (0-99 seconds) for Exit Delay
and Entry Delay. When the system is armed, the Exit Delay time
starts and any activity on Burglary Zones is ignored until the  exit
delay expires. For an Entry Delay, the system must be disarmed
before the delay expires or an alarm condition will occur. Select
the amount of time desired for each delay.

Option 10 Internal Speaker/Siren Annunciation

This option enables the internal speaker to turn on siren tones for
an alarm anytime the Bell Output is turned on. Enter 1 to enable
internal speaker/siren annunciation.

Options 11 Panic Keys

Select 1 to allow two-button panic key operation. Enter 0 to inhibit
panic key operation.

Option 12 Zone 4 Panic or Fire Selection

This option determines Zone 4 operation as either a Panic or
Fire zone. Choose either option 1 for Panic zone without the Bell
Circuit and without LED alarm status (silent), or 2 for Panic zone
with Bell Circuit and LED alarm status, or 3 to select this zone as
a Fire zone.

Option 13 Relay Action

This option is only available in the 741 and 743 keypads and
determines the keypad relay output operation. Enter 1 for alarm
relay, 2  for door access relay operation, or 3 for sensor reset.
When configured as alarm relay, the relay turns on anytime the
Bell Output turns on.

Option 14 Battery Test

Enter 1 when installing a 741 or 743 keypad and battery backup
voltage monitoring is desired. Low battery is detected at 11.9
VDC.

Option 15

This option reserved for future use.

Option 99 Programming Access Code

This option sets the four digit code (0000-9999) for a programming
access code.

Option 00 Exiting the Program Mode

When programming is completed, press the SPECIAL key and 00
to terminate the Program Mode. The Program Mode will be
terminated if no key is pressed for one minute.

Programming Access Code Initialization

The 740, 741, and 743 keypads can be initialized to reset the
programming access code to the factory default (0000). To reset
the programming access code:

Disconnect the Red wire from the 12VDC power source and
disconnect the Red/Black battery wire.

Disconnect the Yellow (data transmit) and the Green (data
receive) wires from the LX-Bus.

Twist the Yellow and Green keypad wires together.

Reconnect the Red wire to the 12VDC power source.

The keypad programmer code is now reset to 0000. Reconnect
wires properly.

Programming the keypad

The SC Series keypads provide a Program Mode that allows installers to configure the keypad.

How to get in

You access the Program Mode by pressing 6,6,5,3 (PROG) followed by a four digit (default = 0000) programming access code. Once
you have accessed the Program Mode you are ready to select the various keypad programming options available. During
programming the Trouble LED will pulse to indicate Program Mode. To enter a programming option press the SPECIAL key followed
by the option number (see the Programming Option Table). Enter the selection for that option. After the selection is entered the keypad
will beep once to accept the programming. If an invalid character  is entered, the keypad will beep four times and exit the option.

Programming Readout

When a programming option is chosen (SPECIAL XX), the current setting for the option is immediately indicated on the Zone 1 LED.

A single programmed digit pulses the Zone 1 LED (1/3 second ON, 1/3 second OFF) the number of times necessary to indicate digit
one through nine. For the zero digit, the LED turns on for 1.5 seconds.

For multiple programmed digits, the Zone 1 LED pulses (1/3 second ON, 1/3 second OFF) the number of times to equal the first digit.
The LED turns off for two seconds, then the LED pulses (1/3 second ON, 1/3 second OFF) the number of times to equal the second
digit. When a programmed option uses two digits but the first digit is zero, only the second digit will be displayed.

Summary of Contents for SC Series

Page 1: ... magnetic locks Alarm Relay connect to an external annunciator Sensor Reset connect to power of 4 wire smoke detector The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC LT 0393 7 98 INSTALLATION PROGRAMMING 740 741 and 743 SC Series LED Keypads 2841 E Industrial Drive Springfield MO 65802 6310 800 641 4282 Wiegand Input A Wiegand style card reader may be at...

Page 2: ...escriptions on the front of the card before inserting the card into the keypad Gently twist while pulling halves apart Repeat at other opening Surface and backbox mounting holes Surface and backbox mounting holes Surface and backbox mounting holes Keypad Mounting Template Installing the keypad The SC Series keypads each use the same plastic housing and are designed to easily install on any 4 squar...

Page 3: ...43 keypads and determines the keypad relay output operation Enter 1 for alarm relay 2 for door access relay operation or 3 for sensor reset When configured as alarm relay the relay turns on anytime the Bell Output turns on Option 14 Battery Test Enter 1 when installing a 741 or 743 keypad and battery backup voltage monitoring is desired Low battery is detected at 11 9 VDC Option 15 This option res...

Page 4: ...ription Range Default 1 X X X SPECIAL 0 1 Programming Initialization 0 No 1 Yes 0 2 X X X SPECIAL 0 2 Clear User Codes 0 No 1 Yes 0 3 X X X SPECIAL 0 3 Bus Address 00 99 00 4 X X X SPECIAL 0 4 LX Bus Communication Style 0 None 1 711 4 714 1 5 SPECIAL 0 5 For future use 6 SPECIAL 0 6 For future use 7 X X X SPECIAL 0 7 Bell Cutoff Time 00 15 Minutes 05 8 X X X SPECIAL 0 8 Exit Delay Time 00 99 Secon...

Reviews: