2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282

2

SC Series Keypad Installation

Keypad harness wiring

Violet - Relay Normally Closed

Green/White - Wiegand Data 0

Output/Reader Harness

Data Bus/Zone Harness

Gray - Relay Common

Orange - Relay Normally Open

White - Wiegand Data 1

Zone 2  White/Red

Zone 3  White/Orange

Zone 1  White/Brown

Zone 4 High  White/Yellow

Red - Keypad Main DC Power Input

Yellow - Send Data to LX-Bus

Green - Receive Data from LX-Bus

Black - Ground

Battery Backup  Red/Black

Bell Switched Ground  Blue

Zone 1, 2, and 3 Ground  Black/White

Zone 4 Low  Yellow/White

Wire

harness

entrances

Combined 4 square and 3-gang

switch box mounting holes.

Insert the reference card

between the two guide tabs

before installing the keypad.

Keypad

Reference

Card

Write the zone

descriptions

on the front of

the card

before

inserting the
card into the

keypad.

Gently twist while pulling halves
apart. Repeat at other opening.

Surface and backbox

mounting holes.

Surface and backbox

mounting holes.

Surface and backbox

mounting holes.

Keypad Mounting Template

Installing the keypad

The SC Series keypads each use the same plastic housing and
are designed to easily install on any 4 square box, 3-gang switch
box, 695 and 696 backbox, or flat surface. The Keypad Mounting
Template below shows the mounting hole location and reference
card location on the keypad base. Use this template as a guide for
mounting the keypad.

Wiring the keypad

The keypads are each supplied with one 12-wire Data Bus /Zone
harness. The 741 and 743 also include one 5-wire Output/Reader
harness. The harness connections and color codes are shown in
the keypad harness wiring diagram.

Once all the wire connections are made, mount the keypad using
appropriate size anchors and the enclosed screws.

Summary of Contents for SC Series

Page 1: ... magnetic locks Alarm Relay connect to an external annunciator Sensor Reset connect to power of 4 wire smoke detector The Form C relay draws up to 30mA of current and its contacts are rated for 1 Amp at 24 VDC LT 0393 7 98 INSTALLATION PROGRAMMING 740 741 and 743 SC Series LED Keypads 2841 E Industrial Drive Springfield MO 65802 6310 800 641 4282 Wiegand Input A Wiegand style card reader may be at...

Page 2: ...escriptions on the front of the card before inserting the card into the keypad Gently twist while pulling halves apart Repeat at other opening Surface and backbox mounting holes Surface and backbox mounting holes Surface and backbox mounting holes Keypad Mounting Template Installing the keypad The SC Series keypads each use the same plastic housing and are designed to easily install on any 4 squar...

Page 3: ...43 keypads and determines the keypad relay output operation Enter 1 for alarm relay 2 for door access relay operation or 3 for sensor reset When configured as alarm relay the relay turns on anytime the Bell Output turns on Option 14 Battery Test Enter 1 when installing a 741 or 743 keypad and battery backup voltage monitoring is desired Low battery is detected at 11 9 VDC Option 15 This option res...

Page 4: ...ription Range Default 1 X X X SPECIAL 0 1 Programming Initialization 0 No 1 Yes 0 2 X X X SPECIAL 0 2 Clear User Codes 0 No 1 Yes 0 3 X X X SPECIAL 0 3 Bus Address 00 99 00 4 X X X SPECIAL 0 4 LX Bus Communication Style 0 None 1 711 4 714 1 5 SPECIAL 0 5 For future use 6 SPECIAL 0 6 For future use 7 X X X SPECIAL 0 7 Bell Cutoff Time 00 15 Minutes 05 8 X X X SPECIAL 0 8 Exit Delay Time 00 99 Secon...

Reviews: