20
Re-lock on Zone 2 Fault (7873 only)
Select NO to leave the relay on when Zone 2 faults to
an open or short condition during bypass. Select YES to
turn the relay off when Zone 2 faults open or short during
bypass. The default is NO.
Activate Zone 3 REX (7873 only)
Select YES to enable the Request–to–Exit feature on Zone
3. When Zone 3 shorts, the keypad relay activates. During
this time, the user can open the protected door to start
the programmed bypass entry/exit timer. If the door is not
opened within the time programmed in the Zone 3 REX
Strike Time, the relay restores the door to its locked state.
No panel programming is required.
Zone 3 REX Strike Time (7873 only)
Enter the number of REX seconds to elapse. Range is from 5
to 250 seconds. Press the display to enter the number. The
default is 5 seconds.
Number of User Code Digits
The keypad recognizes user codes from 4 to 10 digits in
length. Press the display to enter the user code digit length
being used by the panel. Default is 5. When searching the
bit string for the user code, the digits are identified and read
from left to right.
RELOCK ZONE 2
FAULT: NO YES
ACTIVATE ZONE 3
EXIT?
NO YES
ZN 3 REX STRIKE
TIME:
5
NO OF USER CODE
DIGITS: 5
Installer Options