Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. Range is from
5-250 seconds. Press any select area to clear the keypad
display and enter the number of seconds. Default is
5
.
Arming/Disarming Wait Time
Select the number of seconds (1-9) the keypad should wait to
arm and disarm when an area system displays
ALL? NO YES
or a H/S/A system waits during arming only. If
NO
or
YES
,
or
HOME
,
SLEEP
, or
AWAY
is not manually selected before
the delay expires, the keypad automatically selects
YES
or
AWAY
. Enter zero (
0
) to disable this feature. Default is
2
.The
delay also occurs when a credential is presented for arming
the H/S/A system.
For non-Area systems with keypads that have firmware
version 205 or higher, presenting a credential to the keypad
automatically initiates the arming sequence after the arming
wait time expires. All/Perimeter systems arm All. Home/
Sleep/Away and Home/Away systems arm Away.
Security Grade
Select
YES
for security Grade 3. Select
NO
for security
Grade 0 (zero). Default is
NO
.
ZONE 3 REX STRIKE
TIME:
5
ALL?:
NO YES
DELAY:
2
EN 50131
NO
YES