ADEMCO 6152RF Keypad / Transceiver  –  Installation and Setup Guide

Fixed Addressable Keypad/Transceivers for use with Honeywell Control Panels; incorporates normally-open 
relay output with the functions of a 16 zone RF Receiver and a 5800 Transmitter module. 

= READY to Arm

= NOT READY to Arm

= System ARMED

= System NOT ARMED

Programmable Function Keys

Arming Keys

6152RF

: Fixed Word Display

2-Digit Zone Identifier

The ‘21’ digits are used for specific 
trouble indications. Refer to the 
control panel instructions for details.  

ALARM
FIRE

AWAY

BYPASS

STAY

CHECK 

  

INSTANT

CANCELED

NO 

NIGHT

AC

NOT READY
CHIME BAT

TEST

PHONE

6152RF-KEYPAD-LBLD-07-19-13_1

Sounder

 

 

 

 

 

 
 
 
 

Wall
Surface

2

1

SEE Detail 

A

Optional Front Cover Securing Screw
(Required in European Installations)

Install Four (4)
Mounting Screws

Control Panel

1. OPEN

Keypad 
Front 
Cover 

2. WIRE 

3. MOUNT

•  Connect only one wire per terminal.  
•  For Daisy-Chain Configurations, use 
   wire splicing so only one wire is  
   connected to each terminal.

Mount on drywall, or in a single 
or double-gang electrical box.

AUX

RELAY OUTPUT
CONNECTIONS

[  ] GROUND

[Y] DATA IN

[+] +12VDC IN

[G] DATA OUT

Yellow

Black
Red

Green

CONTROL PANEL
TERMINAL STRIP

16-24 AWG Only

KEYPAD

NO

NC

C

DATA

IN

DATA

OUT

AUX

Detail 

A

G

Y

To activate Function keys, 
press and hold key for at 
least 2 seconds; key pairs 
are activated immediately.
 

 

Table 1 – Programmable  
                 Function Keys
 

A or 

 

and 

 

B or 

 and 

 

C or 

 and 

 

D  

 
 

Note:  See the control’s instructions for 
details on programming the Function 
keys for panic alarms or other special 
functions (i.e., macros). 

Programmable to support the 
following : 

-

 Bi-directional 5828/5828V 

wireless keypads and wireless 
keys (e.g., 5804BDV, 5834-4, 
etc.) 

-

  Up to eight button-type wireless 

keys locally (programmed 
directly into the keypad), 
without occupying control panel 
zones 

-

  Up to 16 5800 series wireless 

zones programmed into any 
supported control panel 

-

  Wireless keys with high security 

mode enabled 

Table 2 – Settings Key

Settings Key

Result

Press 

 for 2 Seconds 

Enters Display Test Mode 

Press 

 for 2 Seconds 

and during the Display Test, 

press and hold 

 

and 

 

for 3 Seconds 

Reboots the Keypad (the 
keypad beeps and the ARM 
and READY LEDs flash for 
several seconds) 

 

Summary of Contents for ADEMCO 6152RF

Page 1: ... on drywall or in a single or double gang electrical box AUX RELAY OUTPUT CONNECTIONS GROUND Y DATA IN 12VDC IN G DATA OUT Yellow Black Red Green CONTROL PANEL TERMINAL STRIP 16 24 AWG Only KEYPAD NO NC C DATA IN DATA OUT AUX Detail A G Y To activate Function keys press and hold key for at least 2 seconds key pairs are activated immediately Table 1 Programmable Function Keys A or and B or and C or...

Page 2: ...in the control panel House ID Match Partition 1 House ID in the control panel and House ID in Wireless Device Match House ID in Wireless Device House ID Source System Local Receiver Enable On Off Transmitter Enable On On 4 PROGRAM To program the keypad first enter the Programming Mode select a programming address and set the programming options Refer to the tables below and on the following pages ...

Page 3: ...al devices tE 1 On Enable 0 Off Disable 1 Enable Enable Transmitter Module in only one keypad if more than one 6152RF is used and the House ID source is System Enter 8 Wireless Key Auto Enroll See Programming Local Wireless Keys for Address 8 programming details Wireless Key User Code Wireless Key Loop Function Wireless Key On Board Relay Assignment Enter 9 Restore Defaults EE 1 Restores Defaults ...

Page 4: ...u accept the serial number the display flashes the device number and a hyphen If you reject the serial number the display flashes d with the device number followed by four times Enter 2 Wireless Key User Code Enter the 4 digit user code for the wireless key Note The user code must be a valid code that is programmed in the control panel If the code is deleted or changed in the control the wireless ...

Page 5: ...relay on Press to save the relay assignment Flashes o and the loop number Once the action is entered alternately flashes o and the loop number and the relay action e g alternately flashing o3 and 4 shows Loop 3 will close the relay for 2 seconds Repeat for the wireless key loops where on board relay control is desired When all loops have been programmed for the wireless key press Flashes d followe...

Page 6: ...e Action Lb Low battery in the wireless key 1 Replace the battery in the wireless key OC Open circuit Verify that the Data Out wire is connected properly 1C Incompatible connection Verify that the control panel is not a First Alert type control panel Check 09 OR Check 100 OR Check 10n 1 6152RF Receiver is not communicating 2 Another device on the keypad terminals conflict with this receiver addres...

Page 7: ...couraged to try to correct the interference by one or more of the following measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a...

Page 8: ...nformation please go to www honeywell com security hsc resources wa DOCUMENTATION AND ONLINE SUPPORT For the latest documentation and online support information please go to http www security honeywell com hsc resources MyWebTech Ê800 11537V1 Š 800 11537V1 7 13 Rev A 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2013 Honeywell International Inc www honeywell com secur...

Reviews: