background image

Digital Monitoring Products, Inc.     |     734N Installation and Programming Guide  

39

Output Voltage (POE) 

 

12 VDC

Maximum Power Draw (POE) 

12.95 W

Available Output Current  

750 mA

Zones

 

 

5 VDC, 2 mA max

Dimensions

 

 

4.5W x 2.75H x 1.75D in 

 

 

 

11.43W x 7H x 4.45D cm 

Weight

 

 

8 oz  

.23 kg

Summary of Contents for 734N-POE

Page 1: ...INSTALLATION AND PROGRAMMING GUIDE 734N Wiegand Interface Modules...

Page 2: ......

Page 3: ...als 10 Connect a Card Reader 13 Addressing the 734N 15 TABLE OF CONTENTS Program the 734N 17 Program Start Display 18 Initialization Option 18 Initialize Confirm Option 18 Communication Menu 18 734N D...

Page 4: ...Digits 28 No Communication with Panel 29 Remove Keypad 30 Public Card Formats 31 734N Network Specifications 32 Compliance Listing Specifications 34 UL Access Control 34 ULC Commercial Burglary XR150...

Page 5: ...ndicates that data is being sent to the panel The 734N and 734N POE Wiegand Interface Modules allows you to add IP network access control capability to XR150 XR550 and XR150INT XR550INT Series panels...

Page 6: ...ent See NC C NO Dry Contact Relay and Isolation Relay for more information PROGRAMMING CONNECTION The 734N also provides a keypad programming connection that allows you to use a standard DMP LCD keypa...

Page 7: ...Digital Monitoring Products Inc 734N Installation and Programming Guide 3 PCB FEATURES DC INPUT WIEGAND INPUTS ZONES PIEZO INDICATOR LEDS DOOR RELAY NETWORK CONNECTION Figure 1 PCB Features...

Page 8: ...other flat surface DMP recommends mounting the 734N near the protected door For easy installation the back and ends of the 734N housing have wire entrances The back also contains multiple mounting hol...

Page 9: ...for 10 Amps resistive at 12 24 VDC When connecting multiple locks to the Form C relay the total current for all locks cannot exceed 10 Amps If the total current for all locks exceeds 10 Amps problems...

Page 10: ...ON NC C NO GRN YEL RED Model 333 Supressor Normally Closed Magnetic Door Lock 12 24 VDC Power Supply Figure 3 Typical Magnetic Lock Wiring PROG J2 RED J1 DATA XMT LED WIEGAND READ LED RELAY ON NC C N...

Page 11: ...Digital Monitoring Products Inc 734N Installation and Programming Guide 7 Door Strike POE Switch or Injector Card Reader Figure 5 Typical Door Strike Wiring with POE...

Page 12: ...he Form C relay exceeds 10 Amps an isolation relay must be used Refer to Figures 6 and 7 for isolation relay wiring 3 ISOLATION RELAY Figure 6 Magnetic Lock with an Isolation Relay Figure 7 Door Strik...

Page 13: ...he 734N C common and NO normally open or NC normally closed terminals If the device being controlled by the relay is connected to the NO and C terminals install the suppressor on the NO and C terminal...

Page 14: ...uide for programming instructions See Figure 9 for more information on wiring the zone terminals Auxiliary Outputs 1 2 The 734N controls Auxiliary Outputs 1 and 2 when the Activate Zone 2 Bypass progr...

Page 15: ...Digital Monitoring Products Inc 734N Installation and Programming Guide 11 Figure 9 734N Zone Terminal Wiring Zone 1 Zone 2 Zone 3 Zone 4 1K EOL 1K EOL 1K EOL 1K EOL...

Page 16: ...N or ALL SYSTEM ON Connect the wire from the 4 wire harness to an Armed Status output RA Remote Annunciation Remote Annunciation provides an unsupervised switched ground for a remote annunciator that...

Page 17: ...fferent depending on the reader being installed Refer to the literature provided with the reader for wire coding wire distance cable type such as shielded and other specifications Card Reader LED Oper...

Page 18: ...14 734N Installation and Programming Guide Digital Monitoring Products Inc Figure 10 Card Reader Wiring Card Reader Red 12 24VDC White Data 1 Black GND Green Data 0 Shield Orange Brown Yellow...

Page 19: ...nels are capable of access control expansion using any of the five AX LX Bus headers AX LX500 600 700 800 and 900 An AX Bus address can accommodate 1 door output and 1 expansion zone Because the 734N...

Page 20: ...3 913 916 5 51 54 517 517 520 617 617 620 717 717 720 817 817 820 917 917 920 6 61 64 521 521 524 621 621 624 721 721 724 821 821 824 921 921 924 7 71 74 525 525 528 625 625 628 725 725 728 825 825 82...

Page 21: ...could occur You can also program the 734N from an XR150 XR550 Series panel Initial programming of device and communication must be performed with a keypad Afterwards device programming and 734N option...

Page 22: ...key or area to enter the initialization menu INITIALIZE CONFIRM OPTION After selecting YES to clear the Access Options the 734N displays SURE YES NO for confirmation to clear the memory This is a saf...

Page 23: ...UBNET MASK Enter the local subnet mask assigned to the 734N Default is 255 255 255 0 GATEWAY ADDRESS Enter the local gateway address of the 734N Default is 192 168 0 1 PANEL IP ADDRESS Enter the IP ad...

Page 24: ...anel network programming port Default is 2002 734N PASSPHRASE You must enter an 8 16 character alphanumeric passphrase to encrypt communication with the panel The 734N passphrase must match the 734N p...

Page 25: ...ne 2 When the on board Form C relay activates and the user opens the door connected to zone 2 the zone is delayed for the number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter...

Page 26: ...Strike 40 Second Zone 2 Bypass entry exit timer 10 seconds before the bypass time expires the device beeps if the door is still open End of timer 40 Seconds A zone open short is indicated if the door...

Page 27: ...n open the protected door to start the programmed zone 2 bypass entry exit timer After the programmed number of seconds the relay restores the door to its locked state The 734N module provides a bypas...

Page 28: ...BOARD SPEAKER Select YES to enable the onboard piezo for local annunciation such as alarm and trouble annunciations Select NO to turn the speaker off for all operations This does not affect remote ann...

Page 29: ...t Default is DMP Select CUSTOM if using a non DMP card Select ANY to allow all card reads to activate the door strike relay The door strike relay is activated for the length of time programmed in ZN 3...

Page 30: ...t area 2 to clear the site code start position and enter a number between 0 255 Press CMD to save Default is 1 Press select area 4 to clear the site code length and enter a number between 1 16 Press C...

Page 31: ...ived in the Wiegand string SITE CODE You can program up to eight three digit site codes The site code range is 0 999 Any previously programmed site codes display Dashes represent blank site codes and...

Page 32: ...Repeat these steps to change delete or add other site codes NUMBER OF USER CODE DIGITS The 734 module recognizes user codes from 4 12 digits long Press any select key or area to enter a user code digi...

Page 33: ...but turns off at the end of the door strike timer Press the second select key or area to choose SITE Accept Site Code Door access is granted when the Wiegand site code string received matches any site...

Page 34: ...ys with no time out while the keypad remains connected to the 734N module after programming is finished After five seconds the 734N module piezo continually sounds if the keypad remains connected and...

Page 35: ...D CODE LENGTH SITE CODE POSITION SITE CODE LENGTH USER CODE POSITION USER CODE LENGTH USER CODE DIGITS H10301 26 BIT 26 1 8 9 16 5 H10302 37 BIT W FAC 37 1 16 17 19 6 H10304 37 BIT W O FAC 37 0 0 1 35...

Page 36: ...he remainder of the network All traffic between the 734N and the panel would then be confined to the switch where they are connected while still allowing the panel to communicate with the central stat...

Page 37: ...ion that remains open indefinitely The socket can be closed by the 734N or panel after a time out The connection is re established by the 734N after the time out A pair of supervision packets are sent...

Page 38: ...ource The 734N POE can be powered by a 12 or 24 VDC or UL 294 listed POE switch For listed installations the 734N POE must be installed inside a UL listed DMP metal enclosure such as a Model 350 Refer...

Page 39: ...ontrol System Units Level I Destructive Attack and Line Security Level IV Endurance and Standby Power ANSI UL 609 Local Burglar Alarm Units And Systems ANSI UL 1076 Proprietary Burglar Alarm Units And...

Page 40: ...OE ANSI UL 294 Access Control System Units Level I Destructive Attack and Line Security Level IV Endurance and Standby Power ANSI UL 609 Local Burglar Alarm Units And Systems ANSI UL 1076 Proprietary...

Page 41: ...61000 3 2 Limits Limits for Harmonic Current Emissions Equip Input Current up to and Including 16 A per Phase Includes A1 A2 July 1 2009 EN 61000 3 3 Limitations of Voltage Fluctuations Flicker in Lo...

Page 42: ...es 200 mA for proximity reader 1 6 mA per active zone Alarm 348 mA at 12 VDC includes 200 mA for proximity reader 10 mA with Annunciator ON 2 mA per faulted zone Form C Relay 35 mA at 12 24 VDC When p...

Page 43: ...c 734N Installation and Programming Guide 39 Output Voltage POE 12 VDC Maximum Power Draw POE 12 95 W Available Output Current 750 mA Zones 5 VDC 2 mA max Dimensions 4 5W x 2 75H x 1 75D in 11 43W x 7...

Page 44: ...PROXIMITY READER MX 5375 MAXIPROX PROXIMITY READER PP 6005B PROXPOINT PLUS PROXIMITY READER PP 5355 PROXPRO PROXIMITY READER WITH KEYPAD PR 5455 PROXPRO II PROXIMITY READER TL 5395 THINLINE II PROXIM...

Page 45: ...5 FARPOINTE SMARTCARD READER DELTA5 3 FARPOINTE SMARTCARD READER DELTA6 4 FARPOINTE SMARTCARD READER 13 56 MHZ SMARTCARD CREDENTIALS DC1 1 FARPOINTE CLAMSHELL SMARTCARD DM1 3 FARPOINTE IMAGEABLE SMART...

Page 46: ......

Page 47: ......

Page 48: ...LT 1197C 18512 1 04 2018 Digital Monitoring Products Inc...