26
734N Installation and Programming Guide | Digital Monitoring Products, Inc.
WIEGAND CODE LENGTH
When using a custom credential, enter the total number of bits to be
received in Wiegand code including parity bits. Press any select key
or area to enter a number between 1-255 to equal the number of bits.
Default is
26
bits.
SITE CODE POSITION AND LENGTH
Enter the site code start position and length in the data string. Press
select area 2 to clear the site code start position and enter a number
between 0-255. Press
CMD
to save. Default is
1
.
Press select area 4 to clear the site code length and enter a number
between 1-16. Press
CMD
to save. Default is
8
.
USER CODE POSITION AND LENGTH
Define the user code start bit position and length. Press select area 2
to clear the user code position and enter a number between 0-255.
Press
CMD
to save. Default is
9
.
Press select area 4 to clear the user code length and enter a number
between 16-40. Press
CMD
to save. The default is the DMP value of
16
.
WEIGAND CODE
LENGTH:
26
SITE CODE
POS:
1
LEN:
8
USER CODE
POS:
9
LEN:
16
Summary of Contents for 734N-POE