712-8 INSTALLATION GUIDE     |     DIGITAL MONITORING PRODUCTS 

3

ADDITIONAL INFORMATION

Wiring Specifications

DMP recommends using 18 or 22 AWG for all LX‑Bus and Keypad Bus connections. The maximum wire distance between 

any module and the DMP Keypad Bus or LX‑Bus circuit is 10 feet. To increase the wiring distance, install an auxiliary 

power supply, such as a DMP Model 505‑12. Maximum voltage drop between a panel or auxiliary power supply and any 

device is 2.0 VDC. If the voltage at any device is less than the required level, add an auxiliary power supply at the end of 

the circuit.
To maintain auxiliary power integrity when using 22‑gauge wire on Keypad Bus circuits, do not exceed 500 feet. When 

using 18‑gauge wire, do not exceed 1,000 feet. Maximum distance for any bus circuit is 2,500 feet regardless of wire 

gauge. Each 2,500 foot bus circuit supports a maximum of 40 LX‑Bus devices. 
For additional information refer to the LX‑Bus/Keypad Bus Wiring Application Note (LT‑2031) and the 710 Bus Splitter/

Repeater Module Installation Guide (LT‑0310).

Connecting to Other Modules

Using a 4‑wire connector as an extension of the Keypad Bus or LX‑Bus, you can easily connect the 712‑8 to multiple 

modules on the same bus. Observe wire colors when making connections. For more information about wiring 

connections, refer to Figure 3.

Data LED

The LED on the 712‑8 flashes each time the module responds to a poll from the panel. If there is a problem with the 

panel, system programming, or the connection between the panel and module, the LED stops flashing and a system 

trouble message displays on the keypad.

Compliance Listing Specifications

UL Commercial Burglary

 

The 712‑8 Zone Expansion Module must be mounted inside the control unit enclosure or other Listed enclosure.

ULC Commercial Burglary (XR150/XR550 Series Panels)

 

If the 712‑8 is installed in another enclosure, a DMP Model 307 Clip‑on Tamper Switch programmed as a 24‑Hour zone is 

required.
The 712‑8 zones can only be used in Low Risk applications. Medium or High Risk applications must use panel zone 

inputs.

DMP PANEL 

KEYPAD BUS

712-8 

ADDRESS

EXPANDER ZONES 

1-4              5-8
PANEL ZONES

XT30/XT50 Series, 

XR150/XR550 

Series

1

11‑14

21‑24

2

21‑24

31‑34

3

31‑34

41‑44

4

41‑44

51‑54

XT30/XT50 Series, 

XR150/XR550 

Series

5

51‑54

61‑64

6

61‑64

71‑74

7

71‑74

81‑84

8

81‑84

91‑94

XR550 Series

9

91‑94

101‑104

10

101‑104

111‑114

11

111‑114

121‑124

12

121‑124

131‑134

13

131‑134

141‑144

14

141‑144

151‑154

15

151‑154

161‑164

712-8 

ADDRESS

XR150/XR550 SERIES LX-BUS

PANEL ZONE RANGE

LX-BUS 1

LX-BUS 2

LX-BUS 3

LX-BUS 4

LX-BUS 5

0

500‑507

600‑607

700‑707

800‑807

900‑907

1

501‑508

601‑608

701‑708

801‑808

901‑908

2

502‑509

602‑609

702‑709

802‑809

902‑909

...

...

...

...

...

...

7

507‑514

607‑614

707‑714

807‑814

907‑914

8

508‑515

608‑615

708‑715

808‑815

908‑915

9

509‑516

609‑616

709‑716

809‑816

909‑916

...

...

...

...

...

...

12

512‑519

612‑619

712‑719

812‑819

912‑919

13

513‑520

613‑620

713‑720

813‑820

913‑920

14

514‑521

614‑621

714‑721

814‑821

914‑921

15

515‑522

615‑622

715‑722

815‑822

915‑922

Table 1: Keypad Bus Addresses

Table 2: LX-Bus Addresses

Reviews: