DMP Electronics 5.0 Programming Manual Download Page 5

ePAD Programming Guide 

Digital Monitoring Products

5

Accessing the ePAD

Enter the ePAD default IP Address followed by /admin: For example 192.168.0.251/admin. The Administrator Log 

On screen displays. On the first access to ePAD programming, enter the default Administrator Name and Password: 

ADMIN 

and 

ADMIN

.

Note: 

Be sure that only one administrator is logged on to the ePAD at a time. If two administrators are logged on to 

the ePAD at the same time, conflicts may occur.
After successfully logging on to the ePAD as an administrator, the ePAD Programmer Menu displays. The four 

underlined hyperlinks to the options pages are available for you to use to easily program the ePAD. Click on the 

option to open that page. See Figure 5.
After you complete programming in any of the four Options pages, click 

Submit 

to enter your changes and return to 

the ePAD Programmer Menu. Click 

Reset 

to revert the settings. You may also use the browser Back Arrow to return to 

previous pages.

ePAD System Options Page

This is where you program most ePAD addresses 

discussed in the previous sections under System Options. 

You may also program commercial style hyperlinks in 

System Options. See Figure 6.

Note:

 Changing the IP Address, Gateway Address, HTTP 

Port, or Subnet Mask requires you to reconnect to the 

ePAD using the new values. 

Use caution when changing 

any of these fields. 

After you click 

Submit

, a pop-up 

window appears allowing you to cancel your changes. 

Click 

OK 

only if you are sure you want the changes to be 

saved.
Click 

Cancel 

if you would not like those changes to be 

saved. This allows you to exit if you did not want to 

change such items as the IP Address, Gateway Address, 

HTTP Port, and Subnet Mask.
All addresses, such as the Local IP and Gateway, must follow the conventions for IP Addresses: 12 characters with a 

period after every third character: 192.168.000.251 is the proper format for an address.

Local IP Address 

Enter the ePAD IP address using digits 0 through 9. The default IP Address is 

192.168.000.251

.

Gateway Address

Enter the local gateway address assigned to the ePAD. The default Gateway IP Address is 

192.168.000.125

.

Subnet Mask

Enter the ePAD Subnet Mask using digits 0 through 9. The default Subnet Mask is 

255.255.255.000

.

HTTP Port

Enter the HTTP Port assigned to the ePAD: default is 

80

. The recommended range is 2000 through 65535.

Note:

 If an HTTP Port other than 80 is entered, the HTTP port number must follow the IP Address when entered 

in the address field of the browser. For example, if the HTTP Port is 2005 and the IP Address is 192.168.000.251, 

you would enter http://192.168.000.251:2005. If you are using the Name Registry DNS operation and a domain 

name for the ePAD (such as 

bill.virtualkeypad.com)

, you still need to enter the port number at the end of the 

domain name: bill.virtualkeypad.com:2005. See the 

ePAD Name Registry Options Page

 section.

Keypad Address

Enter the keypad address, 1 to 16, the ePAD is to occupy on the DMP panel keypad bus. The ePAD default 

address is 

4

.

Note: 

If the panel requires Device Setup programming, activate the corresponding device number in Device 

Setup. For example, if 5 is entered for the Keypad Address, enter 5 for Device Type and select Standard for 

Device Type in Device Setup of panel programming. See the Programming Guide for the DMP panel or the 

installing dealer.

Figure 5: ePAD Programmer Menu

Summary of Contents for 5.0

Page 1: ...ramming Cable What is Needed The ePAD installer or the network administrator for a commercial business installation must provide the items listed below For later reference when programming please enter the ePAD IP Addressing information in the spaces provided These instructions explain where to obtain the necessary information Broadband Connection A constant broadband connection such as DSL cable ...

Page 2: ...rs to check their DMP security system status from any computer browser in the world If the ePAD only communicates through a local area network the Gateway IP Address can be left at the default value of 192 168 000 125 A commercial installation site network administrator may provide a Gateway Address Otherwise the Gateway Address should be the same address as the Router Local IP Address For example...

Page 3: ...d com on the next page regarding domain name address and dynamic non static IP address for the ePAD as a Web Server Note A DNS IP Address is not required when the ePAD is communicating to a browser on a local area network and not through the Internet A DNS IP Address is only needed when the Name Registry feature is being used HTTP Port ________________________________ The ePAD is a Web Server and ...

Page 4: ...is process is called Dynamic IP Addressing Services such as the Virtualkeypad com Dynamic DNS Service automatically update your browser so that you can easily connect to the ePAD regardless of whether your IP Address has changed ePAD Internet Router Browser Name Registry DNS 1 ePAD Sends My name is bill and my address is 208 123 4 10 2 ePAD Sends My name is bill and my address is 208 123 4 10 3 Br...

Page 5: ...s you to exit if you did not want to change such items as the IP Address Gateway Address HTTP Port and Subnet Mask All addresses such as the Local IP and Gateway must follow the conventions for IP Addresses 12 characters with a period after every third character 192 168 000 251 is the proper format for an address Local IP Address Enter the ePAD IP address using digits 0 through 9 The default IP Ad...

Page 6: ... wish to show on the ePAD top line display By default the Top Line is blank You may enter any characters when programming through the browser Some special characters do not display properly when you view the programming through a standard 32 character LCD keypad Session Timeout Enter an amount of time from 0 to 99 minutes that the ePAD waits before automatically disconnecting after no activity is ...

Page 7: ... image or text that automatically opens when the user clicks it with the mouse Generally a hyperlink opens a Web site or a document A hyperlink contains a link or path to the Web site or document You may program six hyperlinks from the System Options page Banner Dealer and four Custom Links You can only program the hyperlinks when programming the ePAD through the browser When the user clicks on a ...

Page 8: ...df XR100 http www virtualkeypad com permanent user_guide XR500 pdf XR40 http www virtualkeypad com permanent user_guide XR40 pdf XR20 http www virtualkeypad com permanent user_guide XR20 pdf XR10 http www virtualkeypad com permanent user_guide XR10 pdf XRSuper6 http www virtualkeypad com permanent user_guide XRSuper6 pdf XR6 http www virtualkeypad com permanent user_guide XR6 pdf XR5 http www virt...

Page 9: ... com Unless other Name Registry DNS arrangements have been made do not change the default Server IP Address Note DMP dealers have the option to operate their own Name Registry Dynamic DNS Service to allow their installed ePAD units to update their addresses locally instead of using the DMP virtualkeypad com For additional information contact DMP Technical Service Figure 9 Example of an ePAD Name R...

Page 10: ...set to revert to the current password ePAD Administrator Options Page The ePAD allows one Administrator Name and one Administrator Password which are programmed in the Administrator Options Page When selecting passwords select strong passwords Passwords are not case sensitive Administrator Name Enter one Administrator name consisting of 3 to 16 alphanumeric characters A through Z 0 zero through 9 ...

Page 11: ...8 000 251 Be sure to enter leading zeroes in all IP Addresses If the ePAD is installed behind a router enter a static IP Address for the ePAD within the proper range of the available router IP Addresses GATEWAY ADDRESS 192 168 000 125 Gateway Address Enter the local gateway IP address assigned to the ePAD The default Gateway IP Address is 192 168 000 125 SUBNET MASK 255 255 255 000 Subnet Mask Ent...

Page 12: ...pecial characters such as exclamation points and hyphens The default User Password is NEW Admin name ADMIN Administrator Name Enter one Administrator Name consisting of 3 to 16 alphanumeric characters A through Z 0 zero through 9 Do not use spaces or special characters such as exclamation points and hyphens The default Administrator Name is ADMIN Admin password ADMIN Administrator Password Enter o...

Page 13: ... panel may need to be replaced A few things may hinder the visibility and functionality of the ePAD If you do not see the entire image of the keypad and or the hyperlinks you could be behind a proxy or firewall See the following section titled Proxy Utility Proxy Utility On the rare occasion that the user may access the ePAD using a computer that is behind a proxy such as at work the ePAD Utility ...

Page 14: ... the proxy IP Address or URL Port Enter the proxy port number Proxy Requires Login If you must log in to your proxy to access your ePAD check the Proxy Requires Login box Username Enter the user name required to login to the proxy Password Enter the password required to login to the proxy After you have entered all of the necessary information click OK to close the window Using the ePAD with the P...