PRO-1TE    SERIES 

DIN rail single phase two wire energy meter

 

 

 
 

 
 
 

1.1          Safety instruction 

1.2          Foreword 

1.3          Performance criteria 

1.4          Specifications 

1.5          Basic errors 

1.6          Description

 

1.7          Dimensions 

1.8          Installation 

1.9          Operating 

1.10        Troubleshooting

 

1.11        Technical support 

 
 
 
 
 

User manual

Summary of Contents for PRO-1TE Series

Page 1: ...e phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubl...

Page 2: ...start up ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases...

Page 3: ...ademark of Inepro Industries Ltd member of the Inepro Group The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the...

Page 4: ...capabilities AC voltage withstand 2KV for 1 minute Impulse voltage withstand 6KV 1 2 S waveform Basic current Ib 5A Maximum rated current Imax 45A Operational current range 0 4 Ib Imax Over current wi...

Page 5: ...ver ABS inflammable retarding 1 7 Dimensions Height 117 5 mm Width 18 mm Depth 58 5 mm Weight 0 12 Kg net 1 8 Installation CAUTION Turn off and lock out all power supplying the energy meter and the eq...

Page 6: ...erous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter can be installed on a 35mm DIN rail The meter should be installed in...

Page 7: ...intenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for h...

Page 8: ...ide circuit Check that the power supply indicator is burning If the operating power is too low the spacing interval of the pulses will take some more time this is why it seems like the meter won t cou...

Page 9: ...ts please contact DMMetering dealer in your in your region Your local DMMetering distributor Email support dmmetering com www dmmetering com Inepro Industries Ltd Room 3208 Central Plaza 18 Harbour Ro...