DMMetering PRO-1TE Series User Manual Download Page 2

DMMetering®   

2007                                                                                                                                               

 

 

1.1 Safety instructions 

 

Information for Your Own Safety

 

                            This manual does not contain all of the safety measures for operation of the equipment 

(module, device), because special operating conditions, and local code requirements or 
regulations may necessitate further measures. However, it does contain information 
which must be read for your personal safety and to avoid material damages. This 
information is highlighted by a warning triangle and is represented as follows, 
depending on the degree of potential danger. 

 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 

Warning 

This means that failure to observe the instruction can result in death, serious injury or 
considerable material damage. 
 

        Caution 

This  means  hazard  of  electric  shock  and  failure  to  take  the  necessary  safety 
precautions will result in death, serious injury or considerable material damage. 
 
 
 

Qualified personnel 

Commissioning and operation of the equipment (module, device) described in this 
manual may only be performed by qualified personnel. Qualified personnel in the   
sense of the safety information contained in this manual are persons who are 
authorized to commission, start up, ground and label devices, systems and circuits 
according to safety and Regulatory standards. 

 

Use for the intended purpose 

The equipment (device, module) may only be used for the application cases specified in 
the catalogue and the user manual, and only in connection with devices and 
components recommended and approved by DMMetering. 
 

Proper handling 

The prerequisites for perfect, reliable operation of the product are proper transport, 
proper storage, installation and assembly, as well as proper operation and 
maintenance. When operating electrical equipment, certain parts of this equipment 
automatically carry dangerous voltages. Improper handling can therefore result in 
serious injuries or material damage. 
 

 

 

Use only isolated tools. 

 

Do not connect while circuit is live (hot). 

 

Do not connect the meter to a 3 phase - 400VAC – network. 

 

Place the meter only in dry surroundings. 

 

Do not mount the meter in an explosive area or expose the meter to dust, mildew 
and insects.   

 

Make sure the used wires are suitable for the maximum current of this meter. 

 

Make sure the AC wires are connected correctly before activating the 
current/voltage to the meter. 

 

Do not touch the meter connecting clamps directly with your bare hands, with 
metal, blank wire or other material as you will have the chance of an electrical 
shock. 

 

 

Summary of Contents for PRO-1TE Series

Page 1: ...e phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubl...

Page 2: ...start up ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases...

Page 3: ...ademark of Inepro Industries Ltd member of the Inepro Group The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the...

Page 4: ...capabilities AC voltage withstand 2KV for 1 minute Impulse voltage withstand 6KV 1 2 S waveform Basic current Ib 5A Maximum rated current Imax 45A Operational current range 0 4 Ib Imax Over current wi...

Page 5: ...ver ABS inflammable retarding 1 7 Dimensions Height 117 5 mm Width 18 mm Depth 58 5 mm Weight 0 12 Kg net 1 8 Installation CAUTION Turn off and lock out all power supplying the energy meter and the eq...

Page 6: ...erous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter can be installed on a 35mm DIN rail The meter should be installed in...

Page 7: ...intenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for h...

Page 8: ...ide circuit Check that the power supply indicator is burning If the operating power is too low the spacing interval of the pulses will take some more time this is why it seems like the meter won t cou...

Page 9: ...ts please contact DMMetering dealer in your in your region Your local DMMetering distributor Email support dmmetering com www dmmetering com Inepro Industries Ltd Room 3208 Central Plaza 18 Harbour Ro...