12
Therapy Plus |
User’s Manual
INSPECTION BEFORE USING
Before using the equipment always check the integrity of handpiece and power supply cable. They can
be neither broken, nor twisted, nor crumpled with protection surface cut or internal conductors exposed.
The plastic housing of the handpiece shall not be broken. The optical fiber shall not be damaged.
USING
Press any button to switch on the equipment. To switch it off, press the left and the right buttons
simultaneously until it is off (code “dE” is shown on the display). After 90 seconds inactivity, the
equipment switches off automatically to save the battery.
Select the laser emitter by pressing the left button on the handpiece. Select the energy irradiated by
the respective laser emitter by pressing the right button on the handpiece. The values are indicated
on the display. The irradiation time is adjusted automatically according to the selected energy and
shown on the display, in seconds, as countdown upon pressing the activation button.
To activate the laser emitter, press the switch button. In case of the user wishes to interrupt the laser emis-
sion, just release the switch button. To start the laser emission again starting from the point of interruption,
press the switch button or press the right button to start a new application cycle. At the end of the applica-
tion cycle, the time counter is restarted automatically to the last selected value and the emitter is switched off.
Code “Cb” on the display indicates the end of the battery charge, and the need to be charged. The
battery can be recharged with the handpiece on the support with the power supply connected to it
or with the power supply connected directly to the handpiece.
Full charge of the battery takes approximately 3 hours and it is indicated by one of the blue LEDs
blinking while incomplete and by the display when complete (code “CC”).
When pressing the left and the right buttons simultaneously, the level of the battery charge will be shown
on the display. The level is indicated by code “b”, followed by a number from 1 to 9 (ex. “b5”), where “b1”
indicates minimum charge and “b9”, complete charge, provided that the charger is not connected.
When not used, keep the handpiece on the support to avoid that it falls and to charge the battery.
The equipment will be always in ready mode, i.e., when pressing the switch button, laser will be emitted.
PROCEDURES FOR FINALIZATION
To switch off the equipment, press both left and right buttons simultaneously until it is off. Otherwise,
after 90 seconds inactivity, the equipment switches off automatically to save the battery.