![DMC HX33 Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/dmc/hx33/hx33_operating-instructions-manual_2513663016.webp)
HX33-DS Rev. A
Page 16 / 23
9
Maintenance
DANGER
+
Due to the risk of hand or finger injury, never try to reach into the machine before having
assured that the machine is disconnected from the air supply. Disconnect the air supply
before changing the safety guard and the dies.
CAUTION
+
Connect compressed air supply only with the supplied compressed air hose.
+
Before starting maintenance, disassembly or repair work, the crimp machine must be
disconnected from air supply.
+
Maintenance work may be performed only by authorized and properly trained staff. The
housing and the covers in particular may only be removed by specially trained staff.
+
When working with the HX33 pneumatic crimp machine, do not wear loose clothing,
jewellery or long, loose hair that can get caught in the HX33 pneumatic crimp machine.
+
The crimp machine is only allowed to be used when it is in complete functional condition.
+
The crimp machine is only allowed to be used with mounted dies and safety guard.
+
Work with caution.
+
Only one person is allowed to work on or with the machine at a time.
+
Assure free access to the operating elements of the machine, especially the foot pedal.
+
It is only allowed to work with the specified air pressure.
9.1
Maintenance Plan
DANGER
+
Due to the risk of hand or finger injury, never try to reach into the machine before having
assured that the machine is disconnected from the air supply. Disconnect the air supply
before changing the safety guard and the dies.
CAUTION
+
Before starting maintenance, disassembly or repair work, the crimp machine must be
disconnected from air supply.
+
Maintenance work may be performed only by authorized and properly trained staff. The
housing and the covers in particular may only be removed by specially trained staff.
+
When working with the HX33 pneumatic crimp machine, do not wear loose clothing,
jewellery or long, loose hair that can get caught in the HX33 pneumatic crimp machine.
+
Work with caution.
Regular maintenance and cleaning of the parts which can be reached without opening the
machine will prolong the life of the machine. Do not use rough materials to clean the machine
such as steel wool. The machine and or machine part should not be cleaned with compressed
air. The crimping machine as well as the machine parts must not be cleaned with hard objects
like scrapers, steel wool or similar.
Vacuum heavily soiled parts and wear.
9.1.1
Daily
+
Visual inspection of the HX33 pneumatic crimp machine.
+
Check air pressure (87-116psi / 6-8 bar) of the house installation (manometer not in the
scope of the delivery).
+
Check oil-level of service unit of the house air supply (not in the scope of the delivery).