6. Maintenance

For normal operation, annually re-lubricate both motor bearings with approximately ten (10) drops of 
5W-30 oil. The gears of the gearbox assembly are lubricated with a special high temperature, food grade 
lubricant (SPD-2109) at the time of manufacturing. The level of grease in the gearbox should be checked 
annually and will not normally require further lubrication unless seal breakage occurs. After the grease has 
settled to the bottom of the gearbox, the grease level can be checked. The grease level should not be more 
than 1/4" below the vent plug. 

(See Figure 6A.)

 It may be necessary to insert a wire through vent plug hole 

to determine the grease level. The grease level also can be checked by removing motor and viewing 
grease level through the hole for the motor pinion gear.

Inspect seals annually for signs of leakage (check bearings annually for tightness).

In the event the motor fails to start, check power supply to the motor. If power supply exists and motor still 
fails to start, disconnect power and check blade for freedom of rotation. If power does not exist, check for 
blown fuse or flipped circuit breaker.

If motor stops operating for no apparent reason, wait approximately 5 minutes for the automatic overload 
protection device to reset and reattempt operation. If problem continues, check power supply for voltage 
and check blade of unit for freedom of rotation.

If motor pinion requires removal for any reason, it must be properly installed and located, as shown in the 
parts assembly

 

on Page 18

.

Figure 6A The gear box assembly showing grease level.

WARNING

Disconnect power supply before attempting any type of service. The motor is 
protected with a self-resetting overload protection. 

DANGER

Failure to disconnect power can result in serious injury or death. 

Summary of Contents for FFD-120-WH

Page 1: ...PNEG 258 Scattergrain Grain Spreader Model FFD 120 WH Installation and Operation Manual PNEG 258 Version 1 0 Date 12 09 11...

Page 2: ...2 PNEG 258 Scattergrain Grain Spreader...

Page 3: ...hapter 3 Grain Spreader Assembly Instructions 11 Chapter 4 Installation 12 Grain Spreader Installation 12 Chapter 5 Instructions 14 Operating Instructions 14 Adjustment for Bin Fill 15 Chapter 6 Maint...

Page 4: ...s Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death DANGER WARNING CAUTION NOTICE This is the safety alert symbol It is used...

Page 5: ...clearance Clearance of portable equipment that may be taken to the bin site should also be reviewed and considered Any electrical control equipment in contact with the bin should be properly grounded...

Page 6: ...stallations are made Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good condition Replace missing or damaged safety signs...

Page 7: ...ob Remove all jewelry Tie long hair up and back Wear safety glasses at all times to protect eyes from debris Wear gloves to protect your hands from sharp edges on plastic or steel parts Wear steel toe...

Page 8: ...door on the cover of the 24 porthole door and on the roof manway cover DC 1224 and DC 1225 or similar decals should be present on the bin Please contact the dealer or factory for free replacements All...

Page 9: ...se and suffocate Keep clear of all augers DO NOT ENTER this bin Failure to heed these warnings will result in serious injury or death If you must enter the bin 1 Shut off and lock out all power 2 Use...

Page 10: ...y to peak ring center collar Failure to do so can result in serious injury or death DC 368 Located on the cone segment Stay clear of rotating blade Blade could start automatically Can cause serious in...

Page 11: ...elect the proper number of diverter segments required See diverter segments chart below Diverter Segments Chart NOTE The various types of grain moisture content bin diameter and capacity of fill auger...

Page 12: ...olt hanger extensions to hatch collar 3 Tighten all bolts holding hanger extensions 4 Once unit is installed use a carpenter s level across the top of the spreader cone to confirm it is level in all d...

Page 13: ...it rotates freely without obstruction The motor turns the spreader blade counterclockwise as viewed from above the unit The power spread unit requires 115 volt power supply The minimum wire size is 14...

Page 14: ...y vary according to bin diameter and fill rate See Figure 5A Figure 5A Adjustment of the Tilt 2 Spreader diverters grain guide baffles are used to increase or decrease grain flow resistance over the s...

Page 15: ...tal Always refer to single diverter side as gauge Increase loosen U bolts and pivot the blade single diverter side upward 2 Spreader Diverter Single Side Decrease center filling loosen bolts and rotat...

Page 16: ...he motor pinion gear Inspect seals annually for signs of leakage check bearings annually for tightness In the event the motor fails to start check power supply to the motor If power supply exists and...

Page 17: ...tension Grain is high in center of bin small dough nut Flatten blade increase bite decrease grain flow to spreader Add blade extension Grain is high on one side of bin Level spreader correct grain flo...

Page 18: ...18 PNEG 258 Scattergrain Grain Spreader 8 Power Spreader Parts Assembly Scattergrain Spreader 1 2 HP Parts FFD 120 WH...

Page 19: ...Segments 10 Auger Use 0 Segments 13 S 456 Hex Nut 3 8 16 YDP Grade 5 14 S 1054 Split lock Washer 3 8 ZN 15 SPD 2001 Spreader Blade 16 SPD 2006 Damper 17 SPD 2004 Upper Back Up Plate 18 SPD 2013 GY Dr...

Page 20: ...20 PNEG 258 Scattergrain Grain Spreader NOTES...

Page 21: ...URPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and...

Page 22: ...ties having jurisdiction should be consulted before installations are made Illiana Distribution Center 1004 E Illinois St Assumption Illinois 62510 Phone 1 217 226 5100 Fax 1 217 226 5070 For more inf...

Reviews: