AVERAGING SWITCH INSTALLATION (continued)
4.
Drill a 15/32” hole through the housing next to the bracket and insert a grommet.
Run the cable from the switch through this grommet. Secure the cable to the
bracket using a plastic wire tie ran through the two small holes. Make sure the
cable is protected from oncoming grain by placing the cable and grommet directly
behind the bracket.
5.
Route the cable out of the hopper and to the cab using stick-on clips and ties.
Use a grommet if a hole must be drilled for entry into the cab. Route the sensor
cable about ten inches through the grommet into the Calc-U-Dri box and cut off
excess cable. Remove about three inches of cable housing and connect the
individual wires to the terminal block according to the decal (i.e., black to 11,
yellow to 12 and red to 13.)
See Photo H.
6.
Close the Calc-U-Dri box and tighten the screws in the front corners. Your
Combine Calc-U-Dri is now ready for use.