9.2.7.5 Impulses – Single Shot
:source?:impulse :trigger
Range: none
The single shot command generates a single impulse as soon as the command is received.
9.2.8
Powerline Related Impairments
Frequency
:source?: pwrline :freq <choice> [Hz]
Choice: 50, 60 Hz
9.2.8.1 Metallic Noise Sine Wave Generators
9.2.8.1.1
Harmonic #1 Frequency
:source?: pwrline: metallic: harmonic1 <choice>
Choice: 0 to 6
where
0 = off
1 = fundamental (50/60 Hz)
2 = 2
nd
odd harmonic (150/180 Hz)
3 = 3
rd
odd harmonic (250/300 Hz)
4 = 4
th
odd harmonic (350/420 Hz)
5 = 5
th
odd harmonic (450/540 Hz)
6 = 6
th
odd harmonic (550/660 Hz)
9.2.8.1.2
Harmonic #2 Frequency
:source?: pwrline: metallic: harmonic2 <choice>
Range: 0 to 6
Note that the second frequency is disabled if both frequencies are equal.
9.2.8.2
Level Offset
:Source?: pwrline :metallic: offset <numeric value> [dB] Range:
–10.0 to +10.0 dB
in 0.1 dB steps
To turn off a tone entirely, use the tone frequency command.